DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M66008FP Ver la hoja de datos (PDF) - MITSUBISHI ELECTRIC

Número de pieza
componentes Descripción
Fabricante
M66008FP
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
M66008FP Datasheet PDF : 5 Pages
1 2 3 4 5
MITSUBISHI DIGITAL ASSP
M66008P/FP
ABSOLUTE MAXIMUM RATINGS (Ta = –20 ~ 75°C unless otherwise noted)
Symbol
Parameter
Conditions
VCC
Supply voltage
VI
Input voltage
VO
Output voltage
IIK
Input protection diode current
VI<0V
VI>VCC
IOK
Output incidental diode current
VO<0V
VO>VCC
IGND
Current/GND
GND
Tstg
Storage temperature
16-BIT I/O EXPANDER
Ratings
Unit
–0.5 ~ +7
V
–0.5 ~ VCC + 0.5
V
–0.5 ~ VCC + 0.5
V
–20
mA
20
–20
mA
20
–64
mA
–65 ~ 150
°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VCC
Supply voltage
VI
Input voltage
VO
Output voltage
Topr
Operating temperature
Limits
Unit
Min.
Typ.
Max.
2
6
V
0
VCC
V
0
VCC
V
–20
75
°C
ELECTRICAL CHARACTERISTICS (VCC = 2 ~ 6V unless otherwise noted)
Symbol
Parameter
Conditions
VT+
Threshold voltage in
positive direction
VO=0.1V, VCC–0.1V
|IO|=20µA
CLK, CS
VT–
Threshold voltage in
negative direction
VO=0.1V, VCC–0.1V
|IO|=20µA
S, DI
VIH
High-level input voltage
VO=0.1V, VCC–0.1V
|IO|=20µA
VIL
Low-level input voltage
VO=0.1V, VCC–0.1V
|IO|=20µA
D1~D16
VOL
Low-level output voltage
VI=VT+, VT–
VCC=4.5V
IOL=3mA
IO
Maximum output leak
current
VI=VT+, VT–
VCC=6V
VO=VCC
VO=GND
IIH
High-level input current
VI=VCC
VCC=6V
IIL
Low level input current
VI=GND
VCC=6V
ICC
Static consumption current VI=VCC, GND
VCC=6V
Limits
Ta=25˚C
Ta= –20~75˚C Unit
Min. Typ. Max. Min. Max.
0.35
× VCC
0.8 0.35 0.8
× VCC × VCC × VCC
V
0.2
× VCC
0.65 0.2 0.65
× VCC × VCC × VCC
V
0.75
× VCC
0.75
× VCC
V
0.25
× VCC
0.25
× VCC
V
0.4
0.5 V
1.0
10.0 µA
–1.0
–10.0
0.1
1.0 µA
–0.1
–1.0 µA
10.0
100.0 µA
SWITCHING CHARACTERISTICS (VCC = 5V)
Symbol
Parameter
fmax
Maximum repetition frequency
tPLZ
Output “L-Z”, “Z-L” propagation time
tPZL
CLK-DO
tPLZ
Output “L-Z”, “Z-L” propagation time
tPZL
CS-D1 to D16
tPLZ
Output “L-Z” propagation time S-DO, D1 ~ D16
Conditions
CL=50pF
RL=1k
(Note 2)
Limits
Ta=25˚C
Min. Typ. Max.
2.5
300
300
300
300
300
Ta= –20~75˚C
Min. Max.
1.9
400
400
400
400
400
Unit
MHz
ns
ns
ns
ns
ns
3

Share Link: 