Nvsync : counted number of VSYNC
Nhsync : counted number of HSYNC
¨ V/H SYNC Presence Check
This function checks the input VSYNC, where Vpre flag is set when VSYNC is over 40Hz or cleared when
VSYNC is under 10Hz and the input HSYNC, where Hpre flag is set when HSYNC is over 10Khz or cleared
when HSYNC is under 10Hz.
¨ V/H Polarity Detect
This function detects the input VSYNC/HSYNC high and low pulse duty cycle. If the high pulse duration is
longer than that of low pulse, the negative polarity is asserted; otherwise, positive polarity is asserted.
¨ Composite SYNC separation/insertion
MTL004 continuously monitors the input HSYNC. If the input VSYNC can be extracted from it, a CVpre flag is
set. MTL004 can insert HSYNC pulse during Composite VSYNC’s active time and the insertion frequency
can adapt to the original HSYNC’s.
3.1.8 Auto Tune
Auto Tune function consists of Auto Position which automatically centering the screen and Auto Calibration
which contains Phase Calibration, Histogram, Min/Max Value, and Pixel Grab that are described in the
following paragraphs. With such auto adjustment support it is possible to measure the correct phase,
frequency, gain, and offset of ADC. The horizontal and vertical back porches of input image and the
horizontal and vertical active regions can also be measured. Firmware can adjust input image registers
automatically by reading Auto Tune’s registers in single or burst mode.
¨ Auto Position
MTL004 provides Horizontal/Vertical back porch and active region values. Users can use these values to set
input sample registers to aid in centering the screen automatically.
¨ Phase Calibration
MTL004 provides Auto Calibration registers to measure the quality of current ADC’s phase and frequency.
The biggest Auto Calibration registers value means the right value of ADC’s phase and frequency. MTL004
has two kinds of algorithms to calculate Auto Calibration’s value. One is traditional Difference method,
another is MYSON’s proprietary method. The latter one is recommended for a better performance.
¨ Histogram
Histogram is the total number of input pixels below/above one threshold value for individual R, G, B colors.
This advanced function helps Firmware to analyze ADC performance. Usually Firmware can use the
information to measure ADC’s noise margin, adjust its offset and gain, or even aid in the mode detection.
¨ Min/Max Value
Min/Max value is the minimum or maximum pixel value within the specified input active image region for each
RGB channel. This information is usually used to adjust ADC’s offset and gain.
¨ Pixel Grab
Pixel Grab means user can grab a single input pixel at any one point. The position of the point can be
programmed by the user. This is another traditional method to measure ADC’s phase and frequency.
Revision 0.95