To Top / Lineup / Index
MB40528
s ABSOLUTE MAXIMUM RATINGS (See NOTE)
Parameter
Supply Voltage
Analog Input Voltage
Digital Input Voltage
Storage Temperature
Symbol
VCC
VINA
VIND
Tstg
Condition
–
–
–
–
Rating
-0.5 ~ +7.0
-0.5 ~ VCC +0.5
-0.5 ~ +7.0
-55 ~ +125
(GND = 0V)
Unit
v
v
v
°C
NOTE: Permanent device damage may occur if the above Absolute Maximum Ratings are exceeded. Functional operation
should be restricted to the conditions as detailed in the operational sections of this data sheet. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
s RECOMMENDED OPERATING CONDITIONS
Parameter
Supply Voltage
Analog Input Voltage
Digital “H” Level Input Voltage
Digital “L” Level Input Voltage
Digital “H” Level Output Current
Digital “L” Level Output Current
Clock Frequency
Minimum Clock “H” Level Pulse Width
Minimum Clock “L” Level Pulse Width
Operating Ambient Temperature
Symbol Condition
VCC
–
VINA
–
VIHD
–
VILD
–
IOH
–
IOL
–
fCLK
–
twH
–
twL
–
Top
–
Min.
4.75
VRB
2.0
–
-400
–
–
7.0
8.0
-20
Value
Typ.
5.00
–
–
–
–
–
–
–
–
–
(GND = 0V)
Max.
5.25
VCC
–
0.8
–
1.6
60
–
–
70
Unit
V
V
V
V
µA
mA
MHz
ns
ns
°C
5