MAX7319
I2C Port Expander with Eight Inputs
and Maskable Transition Detection
Table 3. MAX7319 Address Map
PIN CONNECTION
DEVICE ADDRESS
40kINPUT PULLUP ENABLED
AD2
AD0
A6 A5 A4 A3 A2 A1 A0 I7 I6 I5 I4 I3 I2 I1 I0
SCL
GND
1
1
0
0
0
0
0
Y Y Y Y ————
SCL
V+
1
1
0
0
0
0
1
YYYYYYYY
SCL
SCL
1
1
0
0
0
1
0
YYYYYYYY
SCL
SDA
1
1
0
0
0
1
1
YYYYYYYY
SDA
GND
1
1
0
0
1
0
0
Y Y Y Y ————
SDA
V+
1
1
0
0
1
0
1
YYYYYYYY
SDA
SCL
1
1
0
0
1
1
0
YYYYYYYY
SDA
SDA
1
1
0
0
1
1
1
YYYYYYYY
GND
GND
1
1
0
1
0
0
0 ————————
GND
V+
1
1
0
1
0
0
1 ———— Y Y Y Y
GND
SCL
1
1
0
1
0
1
0 ———— Y Y Y Y
GND
SDA
1
1
0
1
0
1
1 ———— Y Y Y Y
V+
GND
1
1
0
1
1
0
0
Y Y Y Y ————
V+
V+
1
1
0
1
1
0
1
YYYYYYYY
V+
SCL
1
1
0
1
1
1
0
YYYYYYYY
V+
SDA
1
1
0
1
1
1
1
YYYYYYYY
A long read sequence (more than 2 bytes) can be used
to poll the expander continuously without the overhead
of resending the slave address. If more than 2 bytes are
read from the expander, the expander repeatedly returns
the input port data followed by the transition flags. The
inputs are repeatedly resampled and the transition flags
repeatedly reset for each pair of bytes read. All changes
that occur during a long read sequence are detected and
reported.
The MAX7319 includes an 8-bit interrupt mask register
that selects which inputs generate an interrupt upon
change. Each input’s transition flag is set when its input
changes, independent of the interrupt mask register
settings. The interrupt mask register allows the processor
to be interrupted for critical events, while the inputs and
the transition flags can be polled periodically to detect
less critical events.
The INT logic ensures that unnecessary interrupts are
not asserted, yet data transitions are detected and
reported regardless of when the transition occurs. The
INT output is not reasserted during a read sequence to
avoid recursive reentry into an interrupt service routine. If
transition occurs during read sequence, the INT assertion
is delayed until the STOP condition, however, INT is not
reasserted upon a STOP condition if the changed input
data is read before the STOP occurs.
Transition-Detection Masks
The transition-detection logic incorporates a transition
flag and an interrupt mask bit for each input port. The
eight change flags can be read through the serial
interface, and the 8-bit interrupt mask is set through the
serial interface.
Each port’s transition flag is set when that port’s input
changes, and the transition flag remains set even if the
input returns to its original state. The port’s interrupt
mask determines whether a transition on that input port
generates an interrupt. Enable interrupts for high-priority
inputs using the interrupt mask. The interrupt allows the
system to respond quickly to changes on these inputs.
Poll the MAX7319 periodically to monitor less-important
inputs. The transition flags indicate whether a permanent
or transient change has occurred on any input since the
MAX7319 was last accessed.
Serial Interface
Serial Addressing
The MAX7319 operates as a slave that sends and
receives data through an I2C interface. The interface uses
a serial data line (SDA) and a serial clock line (SCL) to
achieve bidirectional communication between master(s)
and slave(s). The master initiates all data transfers to
and from the MAX7319 and generates the SCL clock that
synchronizes the data transfer (Figure 1).
www.maximintegrated.com
Maxim Integrated 8