18-Port GPIO with LED Intensity Control,
Interrupt, and Hot-Insertion Protection
WRITE TO OUTPUT PORTS REGISTERS (BLINK PHASE 0 REGISTERS/BLINK PHASE 1 REGISTERS)
SCL 1 2 3 4 5 6 7 8 9
SLAVE ADDRESS
COMMAND BYTE
SDA S A6 A5 A4 A3 A2 A1 A0 0 A 0 0 0 0 0 0 0 1 A MSB
DATA1
LSB A MSB
DATA2
LSB A P
START CONDITION
P7–P0
P15– P8
R/W ACKNOWLEDGE FROM SLAVE
ACKNOWLEDGE FROM SLAVE
ACKNOWLEDGE FROM SLAVE
DATA1 VALID
tDV
tDV
READ FROM INPUT PORTS REGISTERS
SCL
12345678
SLAVE ADDRESS
SDA S A6 A5 A4 A3 A2 A1 A0 1
9
A MSB
COMMAND BYTE
DATA1
START CONDITION
R/W ACKNOWLEDGE FROM SLAVE
P7–P0
P15–P8
DATA1
DATA5
DATA2
tDH
DATA3
LSB A MSB
DATA6
LSB NA P
ACKNOWLEDGE FROM MASTER
DATA4
STOP CONDITION
NO ACKNOWLEDGE FROM
MASTER
DATA6
tDS
INTERRUPT VALID/RESET
SCL 1 2 3 4 5 6 7 8
SLAVE ADDRESS
SDA S A6 A5 A4 A3 A2 A1 A0 1
9
A MSB
COMMAND BYTE
DATA2
START CONDITION
P7–P0
P15–P8
DATA1
R/W ACKNOWLEDGE FROM SLAVE
DATA3
DATA2
LSB A MSB
DATA4
LSB NA P
ACKNOWLEDGE FROM MASTER
STOP CONDITION
NO ACKNOWLEDGE FROM
MASTER
DATA4
INT
tIV
tIR tIV
tIR
STOP
CONDITION
DATA2 VALID
Figure 10. Read, Write, and Interrupt Timing Diagrams
Message Format for Reading
The MAX7314 is read using the MAX7314’s internally
stored command byte as an address pointer the same
way the stored command byte is used as an address
pointer for a write. The pointer autoincrements after
each data byte is read using the same rules as for a
write (Table 2). Thus, a read is initiated by first configur-
ing the MAX7314’s command byte by performing a
write (Figure 7). The master can now read n consecu-
tive bytes from the MAX7314 with the first data byte
being read from the register addressed by the initial-
ized command byte. When performing read-after-write
verification, remember to reset the command byte’s
address because the stored command byte address
has been autoincremented after the write (Table 2). A
diagram of a read from the input ports registers is
shown in Figure 10 reflecting the states of the ports.
Operation with Multiple Masters
If the MAX7314 is operated on a 2-wire interface with
multiple masters, a master reading the MAX7314 should
use a repeated start between the write, which sets the
MAX7314’s address pointer, and the read(s) that takes
the data from the location(s) (Table 2). This is because it
is possible for master 2 to take over the bus after master
1 has set up the MAX7314’s address pointer but before
master 1 has read the data. If master 2 subsequently
changes the MAX7314’s address pointer, then master
1’s delayed read can be from an unexpected location.
Command Address Autoincrementing
The command address stored in the MAX7314 circu-
lates around grouped register functions after each data
byte is written or read (Table 2).