Electrical Characteristics (continued)
(VCC = +3.0V to +5.5V, TA = -40°C to +125°C, unless otherwise specified. Typical values are at VCC = +3.3V and TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
SMBus-COMPATIBLE INTERFACE (SCLK and SDA)
Logic Input Low Voltage
Logic Input High Voltage
Input Leakage Current
Output Low Sink Current
Input Capacitance
SMBus TIMING (Note 2)
VIL
VIH
ILEAK
IOL
CIN
VCC = 3.0V
VIN = GND or 5.5V
VOL = 0.6V
Serial Clock Frequency
fSCLK (Note 3)
Bus Free Time Between STOP
and START Condition
tBUF
START Condition Setup Time
MIN TYP MAX UNITS
0.8
V
2.2
V
-1
+1
µA
6
mA
5
pF
100
kHz
4.7
µs
4.7
µs
Repeat START Condition Setup
Time
START Condition Hold Time
STOP Condition Setup Time
Clock Low Period
Clock High Period
Data Setup Time
Receive SCLK/SDA Rise Time
Receive SCLK/SDA Fall Time
Pulse Width of Spike Suppressed
SMBus Timeout
tSU:STA 90% to 90%
tHD:STA
tSU:STO
tLOW
tHIGH
tHD:DAT
tR
tF
tSP
tTIMEOUT
10% of SDA to 90% of SCLK
90% of SCLK to 90% of SDA
10% to 10%
90% to 90%
(Note 4)
SDA low period for interface reset
50
ns
4
µs
4
µs
4.7
µs
4
µs
250
µs
1
µs
300
ns
0
50
ns
20
28
40
ms
Note 1: All parameters tested at TA = +25°C. Specifications over temperature are guaranteed by design.
Note 2: Timing specifications guaranteed by design.
Note 3: The serial interface resets when SCLK is low for more than tTIMEOUT.
Note 4: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCLK’s falling edge.
www.maximintegrated.com