0.8Ω, Low-Voltage, Single-Supply Dual SPST
Analog Switches
Test Circuits/Timing Diagrams (continued)
V+ 0.1µF
V+ NO_
OR
NC_ *
MAX4741
MAX4742
V+
MAX4743 COM_
IN_
GND
NETWORK
ANALYZER
VIN 50Ω
50Ω
VOUT
MEAS
REF
50Ω 50Ω
MEASUREMENTS ARE STANDARDIZED AGAINST
SHORT AT SOCKET TERMINALS. OFF-ISOLATION IS
MEASURED BETWEEN COM AND “OFF” TERMINAL
ON EACH SWITCH. ON-LOSS IS MEASURED BETWEEN
COM AND “ON” TERMINAL ON EACH SWITCH. SIGNAL
DIRECTION THROUGH SWITCH IS REVERSED; WORST
VALUES ARE RECORDED.
OFF-ISOLATION =
20log
VOUT
VIN
ON-LOSS =
20log
VOUT
VIN
* ADD 50Ω TERMINATION FOR
OFF-ISOLATION
Figure 2. Off-Isolation, On-Loss, and Crosstalk
V+
V+
NO_
OR
NC_
MAX4741
VIN
MAX4742
IN_ MAX4743 COM_
GND
50Ω
RGEN
VGEN
VOUT
CL
1000pF
V+
AS
REQUIRED
V+
NO_
OR
NC_
MAX4741
MAX4742
IN_ MAX4743 COM_
GND
1MHz
CAPACITANCE
ANALYZER
V+
VIN
0
VOUT
MAX4741
MAX4742
∆VOUT
Figure 4. NO_, NC_, and COM_ Capacitance
∆VOUT IS THE MEASURED VOLTAGE DUE TO CHARGE TRANSFER
ERROR Q WHEN THE CHANNEL TURNS OFF.
Q = ∆VOUT x CL
Figure 3. Charge Injection
_______________________________________________________________________________________ 9