DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX2014 Ver la hoja de datos (PDF) - Maxim Integrated

Número de pieza
componentes Descripción
Fabricante
MAX2014 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
50MHz to 1000MHz, 75dB Logarithmic
Detector/Controller
Typical Operating Characteristics (continued)
(Typical Application Circuit (Figure 1), VS = VCC = 3.3V, PIN = -10dBm, fIN = 100MHz, R1 = 0Ω, R4 = 0Ω, RL = 10kΩ, VPWDN = 0V,
TA = +25°C, unless otherwise noted.)
OUTPUT VOLTAGE vs. FREQUENCY
2.0
VCC = 3.6V
1.8
1.6 PIN = -10dBm
1.4
VCC = 2.7V
1.2 PIN = -30dBm
1.0
PIN = -45dBm
0.8
0.6 PIN = -60dBm
0.4
0
VCC = 2.7V, 3.3V, 3.6V
200 400 600 800 1000
FREQUENCY INPUT (MHz)
RF PULSE RESPONSE
2.5
fIN = 100MHz
VOUT
2.0
1.5
1.0
RFIN
(AC-COUPLED)
0.5
0
-0.5
-1.0
TIME (50ns/div)
S11 MAGNITUDE
-10.0
S11 MAGNITUDE
-10.0
-12.5
-15.0
VCC = 2.7V, 3.0V, 3.3V, 3.6V
-17.5
-12.5
-15.0
TA = -20°C
TA = -40°C
-17.5
-20.0
-22.5
-25.0
0
200 400 600 800 1000
FREQUENCY (MHz)
-20.0
-22.5
-25.0
0
TA = +25°C
TA = +85°C
200 400 600 800 1000
FREQUENCY (MHz)
Pin Description
PIN
NAME
DESCRIPTION
1, 4
VCC
Supply Voltage. Bypass with capacitors as specified in the typical application circuits. Place capacitors
as close to the pin as possible (see the Power-Supply Connections section).
2, 3
INHI, INLO Differential RF Inputs
5
PWDN
Power-Down Input. Drive PWDN with a logic-high to power down the IC. PWDN must be connected to
GND for VS between 4.75V and 5.25V with R4 = 75Ω.
6
GND Ground. Connect to the printed circuit (PC) board ground plane.
7
SET
Set-Point Input. To operate in detector mode, connect SET to OUT. To operate in controller mode,
connect a precision voltage source to control the power level of a power amplifier.
8
OUT
Detector Output. In detector mode, this output provides a voltage proportional to the log of the input
power. In controller mode, this output is connected to a power-control input on a power amplifier (PA).
EP
Exposed Pad (TDFN Package Only). Connect EP to GND using multiple vias, or the EP can also be left
unconnected.
8