Absolute Maximum Ratings(Note 1)
Supply Voltage
Input Voltage
Voltage Applied to Disabled Output
Operating Free Air Temperature Range
Storage Temperature Range
Typical θJA
N Package
M Package
7V
7V
5.5V
0°C to +70°C
−65°C to +150°C
51.0°C/W
86.5°C/W
Note 1: The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The “Recommended Operating Conditions” table will define the conditions
for actual device operation.
Recommended Operating Conditions
Symbol
Parameter
Min
VCC
VIH
VIL
IOH
IOL
fCLK
tWCLK
Supply Voltage
HIGH Level Input Voltage
LOW Level Input Voltage
HIGH Level Output Current
LOW Level Output Current
Clock Frequency
Width of Clock Pulse
HIGH
LOW
4.5
2
0
16.5
16.5
tWCLR
Width of Clear Pulse
LOW
10
tSU
Data Setup Time (Note 2)
15↑
tH
Data Hold Time (Note 2)
0↑
tSU
Clear Inactive
12
TA
Free Air Operating Temperature
0
Note 2: The (↑) arrow indicates the positive edge of the Clock is used for reference.
Nom
5
Max
5.5
0.8
−2.6
24
30
70
Units
V
V
V
mA
mA
MHz
ns
ns
ns
ns
ns
ns
°C
3
www.fairchildsemi.com