EM91465 SERIES
TONE/PULSE SWITCHABLE DIALER WITH LCD INTERFACE
AND I.P.P. DETECT FUNCTION
Redialing:
After normal dialing, directly keying F key (or On-Off hook once) and keying RD key on keyboard. The
numbers that are stored into LNB memory will be dialed output.
Repertory memory
The EM91465 series incorporated several sets repertory memory and each one can store number up to 16 digits.
In memory storing, if stored numbers are more than 16 digits that only the previous 16 digits can be stored
into specific memory. Otherwise, these numbers can be stored entirely.
Storing of 13 sets memory types
Direct (one-touch) operation
Off-hook (or turn on HF function), push (ST, d1, d2, .. , dn [ST], EMn or M1~M10 (ROW5 optioned).) The
numbers d1, d2, .. , dn will be stored into memory location “EMn” or Mn. The “EMn” expressed emergency
memory EM1 to EM3. The Mn expressed memory M1~M10.
Indirect (two-touch) operation
Off-hook (or turn on HF function), push (ST, d1, d2, .. , dn, ST, n.) The numbers d1, d2, .. , dn will be stored
into memory location “n”. The “n” expressed digital key from 0 to 9.
Dialing
Direct (one-touch) memory operation
• To select Pulse or Tone mode.
• Off-hook (or Turn on HF function), push Mn (or EMn) key. The numbers that are stored in direct memory
location “Mn (or EMn)” will be dialed out in Pulse or Tone mode as selection. The “n” expressed digital
number from 1~10 decided by dialers’ memory sets.
Indirect (two-touch) memory operation
• To select Pulse or Tone mode.
• Off-hook (or Turn on HF function), push A, n key. The numbers that are stored in indirect memory location
“n” will be dialed out in Pulse or Tone mode as selection. The “n” expressed digital key from 0 to 9.
Pause (P) key operation
The Pause (P) key is designed to support pause operation in dialing duration. “P” key can be stored in memory
and it will occupy one digital position.
• To select Pulse or Tone mode.
• Off-hook (or turn on HF function), push (d1, d2, .. , dn, RD/P, k1, k2, .. , kn.) These numbers will be dialed
out as following sequence:
d1, d2, .. , dn, Tp, k1, k2, .. , kn.