DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS2180A Ver la hoja de datos (PDF) - Dallas Semiconductor -> Maxim Integrated

Número de pieza
componentes Descripción
Fabricante
DS2180A
Dallas
Dallas Semiconductor -> Maxim Integrated Dallas
DS2180A Datasheet PDF : 35 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DS2180A
B8ZS
The DS2180A supports existing and emerging zero suppression formats. Selection of B8ZS coding
maintains system 1’s density requirements without disturbing data integrity as required in emerging clear
channel applications. B8ZS coding replaces eight consecutive outgoing 0's with a B8ZS code word. Any
received B8ZS code word is replaced with all 0’s. B8ZS and bit 7 stuffing modes should not be enabled
simultaneously. Enabling both results in LOS.
TCR: TRANSMIT CONTROL REGISTER Figure 5
(MSB)
ODF
TFPT
TCP
RBSE
TIS
193SI
(LSB)
TBL
TYEL
SYMBOL
ODF
TFPT
TCP
RBSE
TIS
193SI
TBL
TYEL
POSITION
TCR.7
TCR.6
TCR.5
TCR.4
TCR.3
TCR.2
TCR.1
TCR.0
NAME AND DESCRIPTION
Output Data Format.
0 = Bipolar data at TPOS and TNEG.
1 = NRZ data at TPOS; TNEG=0.
Transmit Framing Pass-through.
0 = FT/FPS sourced internally.
1 = FT/FPS sampled at TSER during F-bit time.
Transmit CRC Pass-through.
0 = Transmit CRC code internally generated.
1 = TSER sampled at CRC F-bit time for external CRC insertion.
Robbed Bit Signaling Enable.
1 = Signaling inserted in all channels during signaling frames.
0 = No signaling inserted. (The TTR registers allow the user to
disable signaling insertion on selected DS0 channels.)
Transmit Idle Code Select. Determines idle code format to be
inserted into channels marked by the TIR registers.
0 = Insert 7F (Hex) into marked channels.
1 = Insert FF (Hex) into marked channels.
193S S-bit Insertion. Determines source of transmitted S-bit.
0 = Internal S-bit generator.
1 = External (sampled at TLINK input).
Transmit Blue Alarm.
0 = Disabled.
1 = Enabled.
TYEL TCR.0 Transmit Yellow Alarm.
0 = Disabled.
1 = Enabled.
TRANSMIT BLUE ALARM
The blue alarm (also known as the AIS, Alarm Indication Signal) is an unframed, all 1’s sequence
enabled by asserting TCR.1. Blue alarm overrides all other transmit data patterns and is disabled by
clearing TCR.1. Use of the TIR registers allows a framed, all 1’s alarm transmission if required by the
network.
TRANSMIT YELLOW ALARM
In 193E framing, a yellow alarm is a repeating pattern set of FF(Hex) and 00 (Hex) on the 4 kHz facility
data link (FDL). In 193S framing the yellow alarm format is dependent on the state of bit CCR.3. In all
modes, yellow alarm is enabled by asserting TCR.0 and disabled by clearing TCR.0.
8 of 35

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]