GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency:
Hold-up time:
PUP80 Series:
PUP130 Series:
Line regulation:
Inrush current:
Withstand voltage:
Insulation resistance:
Operating temperature:
Storage temperature:
Relative humidity:
MTBF:
EMI requirements:
Safety requirements:
Switchng frequency
70% minimum Vo > 12V
65% minimum on other models
15msec minimum at 110 VAC
10msec minimum at 110 VAC
±0.5% maximum at full load
15A@115 VAC, or 30A@
230 VAC at 25°C cold start
3000 VAC from input to output
1500 VAC from input to ground
500 VAC from output to ground
10 Mohm minimum from output
to ground
0°C to +60°C (PUP80 series)*
0°C to +70°C (PUP130 series)*
–40°C to +85°C
5% to 95% non-condensing
100,000 hours minimum at
full load at 25°C ambient
In compliance with radiated and
conducted limits of CISPR 22
(EN 55022) Class B and FCC Class B
Approved to:
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950 (EN60950)
60KHz to 75KHz
MECHANICAL SPECIFICATIONS
NOTES:
1. Dimensions shown in inches (mm)
2. Tolerance 0.02 (0.5) Maximum
3. Optional output connectors available
4. Optional ON/OFF switch available
5. DC fan on PUP130 models only
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
PUP80 Series:
PUP130 Series:
Safety ground:
leakage current:
85 to 132 VAC or 170 to 264 VAC
(auto-ranging)
47 to 63 Hz
1.8A (rms) for 115 VAC
1.0A (rms) for 230 VAC
3.0A (rms) for 115 VAC
1.7A (rms) for 230 VAC
0.40mA max. @ 110VAC 60 Hz
0.80mA max. @ 240VAC 50 Hz
OUTPUT SPECIFICATIONS
Total output power: See rating charts
Ripple and noise:
1% peak to peak maximum
Overvoltage protection: Set at 112-132% of its
nominal output voltage
Overcurrent protection: Protected under short circuit conditions
Temperature coefficient: ±0.04%/°C maximum
Transient response: Maximum excursion of 4% or better
on all models, recovering to 1% of
final value 500us after a 25% step
load change
Remote sense:
Optional, please consult factory
* PUP80: Derate linearly from 100% load at 40°C to 50% load at 60°C
* PUP130: Derate linearly from 100% load at 50°C to 50% load at 70°C
AC INPUT IEC 320 INLET
2.50 (63.5)
PIN CHART
Model
All Models
PIN
1
2
3
4
5
6
7
8
RETURN RETURN OUTPUT RETURN OUTPUT RETURN OUTPUT OUTPUT
+V
+V
+V
+V
International
Power Sources, Inc.
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100