DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MX805AP Ver la hoja de datos (PDF) - MX-COM Inc

Número de pieza
componentes Descripción
Fabricante
MX805AP
MX-COM
MX-COM Inc  MX-COM
MX805AP Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Sub-Audio Signaling Processor
11
MX805A
5.2 Address/Commands
The first byte of a loaded data sequence is always recognized by the C-BUS as an Address/Command (A/C)
byte. Instruction and data transactions to and from this device consist of an Address/Command byte followed
by either:
(i) further instructions or data
(ii) a Status or data Reply
Instructions and data are loaded and transferred, via C-BUS, in accordance with the timing information in
Figure 9 and Figure 11.
Placing the Address Select input at a logic “0” will address MX805A #1, a logic “1” will address MX805A #2.
Table 4 and Table 5 show the list of A/C bytes relevant to the MX805A
Command Assignment
General Reset
Write to Control Register
Read Status Register
Read CTCSS Rx Freq. Reg.
Write to CTCSS Tx Freq./NRZ
Baud Rate Reg.
Read NRZ Rx Data Reg.
Write to NRZ Tx Data Reg.
Write to Gain Set Reg.
Address/Command (A/C) byte
Hex
Binary
MSB
LSB
01
00000001
70
01110000
71
01110001
72
01110010
73
01110011
74
01110100
75
01110101
76
01110110
Data Bytes
+1 byte instruction to Control
Register
+1 byte reply from Status Register
+2 byte reply of CTCSS Rx Data
+2 byte instruction for Tx Frequency
and NRZ Tx/Rx baud rates
+1 byte binary data Reply
+1 byte binary data Command
+1 byte instruction for Tx Output
Table 4: MX805A #1 C-BUS Address/Commands – (Address Select input at a logic “0”)
Command Assignment
General Reset
Write to Control Register
Read Status Register
Read CTCSS Rx Freq. Reg.
Write to CTCSS Tx Freq./NRZ
Baud Rate Reg.
Read NRZ Rx Data Reg.
Write to NRZ Tx Data Reg.
Write to Gain Set Reg.
Address/Command (A/C) byte
Hex
Binary
MSB
LSB
01
00000001
78
01111000
79
01111001
7A
01111010
7B
01111011
7C
01111100
7D
01111101
7E
01111110
Data Bytes
+1 byte instruction to Control
Register
+1 byte reply from Status Register
+2 byte reply of CTCSS Rx Data
+2 byte instruction for Tx Frequency
and NRZ Tx/Rx baud rates
+1 byte binary data Reply
+1 byte binary data Command
+1 byte instruction for Tx Output
Table 5: MX805A #2 C-BUS Address/Commands – (Address Select input at a logic “1”)
1998 MX-COM, Inc.
www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054
Doc. # 20480116.004
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA
All trademarks and service marks are held by their respective companies.