DS2401
NOTES:
1) All voltages are referenced to ground.
2) VPUP = external pullup voltage.
3) Input load is to ground.
4) An additional reset or communication sequence cannot begin until the reset high time has expired.
5) Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1µs of this falling edge and will remain valid for 14µs minimum (15µs
total from falling edge on 1-Wire bus).
6) VIH is a function of the external pullup resistor and VPUP.
7) 30 nanocoulombs per 72 time slots at 5.0V.
8) At VPUP= 5.0V with a 5kpullup to VPUP and a maximum time slot of 120µs.
9) Capacitance on the I/O pin could be 800pF when power is first applied. If a 5kresistor is used to
pullup the I/O line to VPUP, 5µs after power has been applied the parasite capacitance will not affect
normal communications.
10) The reset low time (tRSTL) should be restricted to a maximum of 960µs, to allow interrupt signaling,
otherwise it could mask or conceal interrupt pulses if this device is used in parallel with a DS2404 or
DS1994.
11) The optimal sampling point for the master is as close as possible to the end time of the tRDV period
without exceeding tRDV. For the case of a Read-One Time slot, this maximizes the amount of time for
the pullup resistor to recover to a high level. For a R ead-Zero Time slot, it ensures that a r ead will
occur before the fastest 1-Wire device(s) releases the line.
12) The duration of the low pulse sent by the master should be a minimum of 1μs with a maximum value
as short as possible to allow time for the pullup resistor to recover the line to a high level before the
1-Wire device samples in the case of a Write-One Time or before the master samples in the case of a
Read-One Time.
PACKAGE INFORMATION
For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages. Note that a “+”,
“#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the
drawing pertains to the package regardless of RoHS status.
PACKAGE TYPE
PACKAGE CODE
OUTLINE NO.
LAND PATTERN NO.
3 TO-92
(straight leads)
3 TO-92
(formed leads)
6 TSOC
Q3+1
Q3+4
D6+1
21-0248
21-0250
21-0382
90-0321
4 SOT-223
K3+1
21-0264
2 Flip Chip
BF211#1
21-0378
Refer to 21-0378
10 of 11