2.6.Power Supply ON/OFF Sequence
2.6.1.ON Sequence
SIGNAL
VCC
SIGNAL
VADJ
VEE
0≦t
0≦t
LEVEL
VCC
VSS
VCC
VSS
VCC
VSS
VADJ
VEE
2.6.2.OFF Sequence
LEVEL
VCC
VSS
VCC
VSS
VCC
VSS
VADJ
VEE
0≦t
0≦t
SIGNAL
VCC
SIGNAL
VADJ
VEE
Please maintain the above sequence when turning on and off the power supply of the module.
If VEE and/or VADJ is supplied to the module while internal alternate signal for LCD driving
(M) is unstable, DC component will be supplied to the LCD panel. This may cause damage
the LCD module.