5. Environmental condition:
5.1. Resistibility to overvoltages and overcurrents:
The splitter has to comply with requirements as per ITU-T K.21.
5.2. Climatic conditions:
5.2.1. Operating temperature:
Application
indoor
Long time operation guarantee temperature ( 5 to 40 0C )
Short time operation guarantee temperature ( 0 to 50 0C )
( According to ETS 300 019, class 3.2 )
5.2.2. Storage and transport:
Low ambient temperature
- 20 0C
High ambient temperature
+85 0C
( According to MIL-STD-202 method 107 )
5.2.3. Operation humidity:
Long time operation guarantee humidity ( 5 to 85 % )
Short time operation guarantee humidity ( 5 to 90 % )
Short time : within 72 continuous hours and 15 days in a year
6. Reliability conditions:
6.1. Thermal shock :
Temperature from -20 °C to +85 °C for 5 cycles
(According to MIL-STD-202 , method 107)
6.2. Temperature humidity exposure :
+50 °C /95RH , 96hrs
(According to MIL-STD-202 , method 103)
6.3. Vibration test :
Random vibration , frequency 5-500Hz , sweep time :1 hr / axis /
Force : 2.4grams (According to MIL-STD-202 , method 204)