Product Specification
MF606G
4.5. Test method:
4.5.1. Insertion loss:
The insertion loss of a device connected into a given transmission system is
defined as the ratio, expressed in dB, of the load power available(before and after
insertion ) delivered to the output network beyond the point of insertion at a given
frequency. In general , the insertion loss of a device inserted in a given
transmission system mainly caused by internal component resistive loss while all of
the impedance between source , load and device interface having been matched.
To perform the insertion loss measurement ,thru calibration must be done prior the
testing . General Insertion loss equation can be expressed as following
Insertion loss = 20 log V2 / V1 dB where
V1 = the measured voltage value of load without LPF in circuit.
V2 = the measured voltage value of load with LPF in circuit.
The test setup is shown in drawing below :
Data sheet subject to change without notice
RDPS-MF063(R1)01/15/2003