Advance Information
MH88615
AC Electrical Characteristics*
Characteristics
1 Ringing voltage
2 Ring Trip Detect Time
3 Input Impedance at VR
4 Output Impedance at Vx
5 Gain 2-wire to Vx
6 Frequency Response 2-wire to Vx
Sym
VR
FR
Min Typ
38
17
100
47 100
10
-0.25 0
-0.15 0
Max
68
0.25
0.15
Units
Vrms
Hz
ms
k
dB
dB
Test Comments
Superimposed on
VBat= -48V. RV=1.5
Vrms
Relative to 1kHz
300Hz to 3.4 kHz
7 Gain Vr to 2-wire
8 Frequency Response Vr to 2-wire
-0.25 0
-0.15 0
9 Total Harmonic Distortion
THD
10 Common Mode Rejection Ratio
CMRR 50
11 Idle Channel Noise
Nc
12 Power Supply Rejection Ratio at 2- PSRR 25
Wire or VX
0.25
0.15
0.5
12
dB
dB
%
dB
dBrnC
dB
Relative to 1kHz
300 Hz to 3.4 kHz
Ripple 0.1V
1kHz @ VDD
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
‡ Typical figures are at 25°C and are for design aid only.
Note 1: All of the above test conditions use a test source impedance which matches the device’s impedance.
Note 2: THD is measured with “A Weight” filter.
AC Electrical Characteristics*- MH88615-1
Characteristics
Sym Min Typ Max Units
Test Comments
1 Ringer Equivalence
2 Return Loss
3 Transhybrid Loss
4 Longitudinal to
Metallic Balance
REN
5
RL
20
24
20
THL
24
32
54
1 REN= 8000
@ 25 Hz
dB 200 Hz - 500 Hz
dB 500 Hz - 2.5 kHz
dB 2.5kHz - 3.4 kHz
dB 300 Hz - 3.4 kHz
dB 50 Hz - 300 Hz
dB 300 Hz - 4 kHz
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Note: Return Loss reference impedance are defined by variant type.
Transhybrid Loss is measured when terminated with network impedance.
AC Electrical Characteristics*- MH88615-3
Characteristics
Sym Min Typ Max Units
Test Comments
1 Ringer Equivalence
2 Return Loss
3 Transhybrid Loss
4 Longitudinal to
Metallic Balance
REN
4
RL
20
THL
20
52
4 REN= 2200
@ 25 Hz
dB 300 Hz - 3.4 kHz
dB 300 Hz - 3.4 kHz
dB 300 Hz - 3.4 kHz
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Note: Return Loss reference impedance are defined by variant type.
Transhybrid Loss is measured when terminated with network impedance.
2-143

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]