Electrical Characteristics (continued)
Unless otherwise specified, VCC = 15V, RT = 12.7kΩ, CT = 250pF, RCLK = 3kΩ, RDELAY = 5kΩ, TA = Operating
Temperature Range (Note 1).
Parameter
Conditions
Min. Typ. Max.
Output
Output Low Level
Output High Level
Rise/Fall Time
IOUT = 20mA
IOUT = 200mA, TA = 25°C
IOUT = –20mA
IOUT = –200mA, TA = 25°C
CL = 1000pF
0.1 0.4
0.7 2.8
12.0 13.5
11.0 13.0
50 75
Under-Voltage Lockout
Start Threshold
15.5 16.5 17.2
Stop Threshold
9.25 10.2 10.7
Supply
Start Up Current
VCC<15.8V
3
4
ICC
VINV = 4V, VRAMP = VILIM = 0V, CL = 1nF,
TA = 25°C (Note 2)
60 70
Notes
1. Limits are guaranteed by 100% testing, sampling, or correlation with worst-case test conditions.
2. VCC must be brought above the UVLO start voltage (17.2V) before dropping to VCC = 15V to ensure start-up.
Units
V
V
V
V
ns
V
V
mA
mA
5