Doc No.: 400035745
Issued Date: 02,Oct, 2009
Model No.: M215H1-L03
Approval
Note (4) Definition of Luminance of White (LC):
Measure the luminance of gray level 255 at center point
LC = L (5)
L (x) is corresponding to the luminance of the point X at Figure in Note (6).
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for (30 minutes) to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for (30 minutes) in a windless room.
LCD Module
LCD Panel
USB2000
CS-1000T
Field of View = 1º
Center of the Screen
500 mm
Light Shield Room
(Ambient Luminance < 2 lux)
Note (6) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 9 points
δW = Maximum [L (1) ~ L (9)] / Minimum [L (1) ~ L (9)]
Horizontal Line
D
D/10
D/2
D/10
W/10
1
2
3
W W/2
4
W/10
7
5
8
Active Area
20 / 27
6
X : Test Point
X=1 to 9
9
Version 2.0