APPLICATION - HINTS
1. CW - capability of the CGY180
1.1 VD = 3 V
Proving the possibility of CW - operations there must be known the total power dissipation of the
device. This value can be found as a function of the temperature in the datasheet (page 8/14). The
CGY180 has a maximum total power dissipation of Ptot = 2.3 W.
As an example we take the operating point with a drain voltage VD = 3 V. The possible ratings of
the drain current adjusted by the internal current control of the CGY180
( VG = -4 V, VTR = 0 V ) are shown in the following table.
Min.
ID / mA
325
Typ.
Max.
450
650
At worst case you see a current of ID = 650 mA. So the maximum DC - power can be calculated to
PDC = VD ID = 1.95W
This value is smaller than 2.3W and CW - operation is possible.
1.2 VD = 4 V
If you want to use the whole capability of the CGY180, you must consider the power added
efficiency PAE. You want to take an operation point of VD = 4 V. Now there will be a higher
current than at VD = 3 V. We assume a current of ID = 650 mA and a PAE = 35 %. With these
values the DC - power is PDC = 2.6 W. That exeeds the PtotDC of 2.3 W. Decoupling RF-Power
from the CGY180 results in less power dissipation of the device. This is directly correlated with the
achieved PAE. To calculate total power dissipation use the formula:
( ) PtotDC = PDC 1PAE .
Ptot for the used operating point shown above will be
Ptot = 2.6W (1 0.35) = 1.69W .
It is possible to use the CGY180 for CW - operations up to a drain voltage of VD = 4 V, if at the
same time a PAE of 35% is achieved.
The calculation can be done for any operating point to prove the capability of CW - operation.
Siemens Aktiengesellschaft
pg. 14/15
21.02.96