CGY 180
2. Not Using the Internal Current Control
If you don’t want to use the internal current control, it is recommended to connect the
negative supply voltage at pin 1 (VTR) instead of pin 2 (VG).
3. Biasing and Use Considerations
In all cases, RF input power should not be applied until the bias voltages have been
applied, and RF input power should be turned off prior to removing the bias voltages.
Bias application should be timed such that gate voltage (VGG) is always applied before
the drain voltages (VDD), and when returning to the standby mode, gate voltage should
only be removed once the drain voltages have been removed.
Data Book
16
03.00