4.4.3. Filter attenuation test :
4.4.3.1. Test equipment :
a. HP4395A Network / Spectrum / Impedance Analyzer
b. HP87512A Transmission / Reflection test set
c. Balun North Hills : 0311LB(50Ω : 100Ω);0511LB(50Ω : 150Ω)
4.4.3.2. Test setup: is shown in Fig. 8
4.4.3.3. Test procedure :
a. Set HP4395A in B/R mode.
b. Connecting the Analyzer to the ISDN/POTS and ADSL side of splitter through the
North Hills 0311LB and 0511LB(50Ω : 150Ω).
c. Set frequency of interest given in specification.
d. Calibrating the HP4395A network Analyzer via the thru.
e. Measurement attenuation.
Fig. 8