Data Sheet - Application Information
9 Application Information
Error Detection
The AS1113 features two types of error detection. The error detection can be used on-the-fly, for active LEDs, without
any delay, or by entering into low-current diagnosis mode.
Error Detection On-The-Fly
Error detection on-the-fly will output the status of active LEDs during operation. Without choosing an error mode this
will output the temperature flag at every input/output cycle. Triggering one clock pulse for open or two clock pulses for
short detection during error detection mode outputs the detailed open- or short-error report with the next input/output
cycle (see Figure 18). LEDs turned off at test time are not tested and will show a logic "1" at the detailed error report.
Figure 18. Normal Operation with Error Detection During Operation – 64 Cascaded AS1113s
Display
Data1
Data2
Data3
SDI
Data2
Data3
Data4
SDO
CLK
OEN
LD
T/O or S Error Code
Data0
GEF
1024x
Clock for Error
Mode 0x/1x/2x
Rising Edge of OEN
Acquisition of Error Status
T/O or S Error Code
Data1
1024x
GEF
Clock for Error
Mode 0x/1x/2x
Rising Edge of OEN
Acquisition of Error Status
T/O or S Error Code
Data2
1024x
Falling Edge of LD; Error Register is
copied into Shift Register
Falling Edge of LD; Error Register is
copied into Shift Register
Current
50mA
GEF = Global Error Flag
Error Detection with Low-Current Diagnosis Mode
This unique feature of the AS1113 uses an internal all 1s test pattern for a flicker free diagnosis of all LEDs. This error
detection mode can be started at the end of each input cycle (see Figure 19).
Figure 19. Low-Current Diagnosis Mode with Internal All 1s Test Pattern – 64 Cascaded AS1113s
Low-Current Diagnosis Mode
Display
Data0
Data1
Data2
SDI
SDO
CLK
OEN
LD
Current
Data1
Data2
T/O or S Error Code
Data0
1024x
GEF
O oArllS1sErTGreoEsrtFCPoadtteerfrnom
3x Clocks Low- Clock for Error
Current Mode Mode 1x/2x
1024x
Rising Edge of OEN
Acquisition of Error Status
GEF
Use Internal All 1s Falling Edge of LD; Error Register
Test Pattern is copied into Shift Register
50mA
0.8mA
50mA
Data3
Temperature Error Code
1024x
GEF = Global Error Flag
www.austriamicrosystems.com