Application circuit 1
Control signal input
TA7259P/F/FG
Normal/Reverse SW
Position detection.
Constant voltage/
constant current drive.
(Constant current drive
is shown in this figure.)
TA7259
P/F/FG
Hall supply
Coil current
※ 1:
※ 2:
※ 3:
VZ of zenner diode should correspond to DC level of control signal input.
(VZ = 2.5〜9V. In considering temperature characteristics, applying 5V is recommended. DC voltage of
negative control input (VIN−pin) equals VZ+RF・IL.
RF is determined by the coil impedance, F/V converter voltage (control input), and necessary starting torque.
However, please apply within the range of 0.3 to 5Ω.
Connect this condenser when there is a plunge in control input.
Application circuit 2
Control signal input
Position sensing device
TA7259
P/F/FG
Normal/Reverse SW
Note:
Utmost care is necessary in the design of the output, VCC, VM, and GND lines since the IC may be
destroyed by short-circuiting between outputs, air contamination faults, or faults due to improper grounding, or
by short-circuiting between contiguous pins.
12
2006-4-14