DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

RAC40-24SB Ver la hoja de datos (PDF) - Unspecified

Número de pieza
componentes Descripción
Fabricante
RAC40-24SB
ETC
Unspecified ETC
RAC40-24SB Datasheet PDF : 3 Pages
1 2 3
Features
Regulated
Converters
Description
Compact 40W AC-DC Power Supply
Universal Input Voltage Range
3000VAC Isolation
Low Output Ripple and Noise
Short Circuit Protected
Triple Output with Independent Outputs
Suitable for Industrial Applications
CE Marked
Compact switching power module for PCB or DIN-rail mounting
Selection Guide
Part
Number
RAC40-05SB
Input
Range
(VAC)
90-264
Output
Voltage
(VDC)
5
Output
Current
(mA)
8000
Efficiency
(%)
81
Max.
Capacitive
Load
40000µF
RAC40-12SB
90-264
12
3333
84
8600µF
RAC40-15SB
90-264
15
2666
83
6600µF
RAC40-24SB
90-264
24
1667
83
1400µF
RAC40-05DB
90-264
±5
±4000
81
±12000µF
RAC40-12DB
90-264
±12
±1666
83
±4400µF
RAC40-15DB
90-264
±15
±1333
83
±1000µF
RAC40-0512DB 90-264
5/12
5000/1250
82
10000/470µF
RAC40-0512TB 90-264
5/±12
+5000/±600
82 10000/±780µF
RAC40-0515TB 90-264
5/±15
+5000/±500
81 10000/±900µF
*add suffix "-ST” for screw terminal module e.g. RAC40-05SB-ST, RAC40-05DB-ST, RAC40-0512TB-ST
Specifications (typical at 25°C and after warm up time unless otherwise specified )
Input Voltage Range
90-264VAC or 100-375VDC
Rated Power
40 Watts max.
Input Frequency Range (for AC Input)
47-440Hz
Input Current (full load)
115VAC/230VAC
860mA/ 460mA max.
No Load Power Consumption
115VAC/230VAC
720mW max.
Inrush Current (<2ms)
115VAC/230VAC
30A / 50A max.
Leakage Current
0.75mA max.
Holdup time
Output Voltage Accuracy (Full load) (2)
10ms min.
Single, Dual Outputs ±2% typ.
Double/Triple: Main Output ±3% typ., Secondary Output(s) ±5% typ.
Line Voltage Regulation (low line, high line at full load )
Single, Dual Outputs ±0.5% typ.
Double/Triple: Main Output ±0.5% typ., Secondary Output(s) ±5% typ.
Load Voltage Regulation
(1% to 100% Load)
Single: ±1% typ.
(10% to 100% Load)
Dual: Main Output ±1% typ., Secondary Output ±1% typ.
(10% to 100% Load)
Double: Main Output ±2% typ., Secondary Output ±6% typ.
(10% to 100% Load)
Triple: Main Output ±3% typ., Secondary Outputs ±7% typ.
Cross Regulation
Dual: Main Output ±5%, Secondary Output ±5% typ.
Double: Main Output ±1% typ., Secondary Output ±7% typ.
Triple: Main output ±3% typ., Secondary Outputs ±7% typ.
Output Ripple and Noise (20MHz limited, 0.1µF and 47µF across outputs)
1% Vout max.
Operating Frequency
132kHz typ.
RMS Isolation Voltage (input to output)
3kVAC / 1 minute
Temperature Coefficient
±0.01%/°C typ.
Isolation Resistance
100 MΩ min.
Short Circuit Protection
Continuous, Automatic Restart
Overcurrent Protection
105% typ.
Over Temperature Protection
tc=100°C thermal shutdown, auto restart after cool down
Operating Temperature Range (free air convection, with derating)
-40°C to +70°C
Storage Temperature Range
-40°C to +85°C
continued on next page
www.recom-power.com
REV: 1/2016
POWERLINE
AC/DC-Converter
with 3 year Warranty
40 Watt
Single/Dual/
Double &
Triple Output
RoHS
2011/65/EU
6/6
RAC40-B
Derating-Graph
(Ambient Temperature)
125
100
75
Natural Convection
50
40
25
0
-40 -25 -10 0 30 40 60 70 80 90
50
Ambient Temperature Range (°C)
PA-51

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]