Standard Specification List
200-V Class
Item
Model name (3G3JX-)
Applicable motor
kW
capacity *1
HP
Rated output capacity
(kVA)
200 V
240 V
Rated input voltage
Built-in filter
Rated input current (A)
Rated output voltage *2
Rated output current (A)
Weight (kg)
Cooling method
Braking torque
At short-time
deceleration *3
At capacitor
feedback
DC injection
braking
3-phase 200-V class
A2002
A2004
A2007
A2015
A2022
0.2
0.4
0.75
1.5
2.2
1/4
1/2
1
2
3
0.4
0.9
1.3
2.4
3.4
0.5
1.0
1.6
2.9
4.1
3-phase (3-wire) 200 V 15% to 240 V +10%, 50/60 Hz ±5%
Zero-phase reactor
1.8
3.4
5.2
9.3
13.0
3-phase: 200 to 240 V (Cannot exceed that of incoming voltage.)
1.4
2.6
4.0
7.1
10.0
0.8
0.9
1.1
2.2
2.4
Self-cooling
Forced-air-cooling
A2037
3.7
5
5.5
6.6
20.0
15.9
2.4
Approx. 50%
Approx. 20% to 40%
Injection braking frequency/time, braking force variable, frequency control available
400-V Class
Item
Model name (3G3JX-)
Applicable motor
kW
capacity *1
HP
Rated output capacity
(kVA)
380 V
480 V
Rated input voltage
Built-in filter
Rated input current (A)
Rated output voltage *2
Rated output current (A)
Weight (kg)
Cooling method
Braking torque
At short-time
deceleration *3
At capacitor
feedback
DC injection
braking
3-phase 400-V class
A4004
A4007
A4015
0.4
0.75
1.5
2.2
1/2
1
2
3
0.9
1.6
2.5
3.6
1.2
2.0
3.1
4.5
3-phase (3-wire) 380 V 15% to 480 V +10%, 50/60 Hz ±5%
Zero-phase reactor
2.0
3.3
5.0
7.0
3-phase: 380 to 480 V (Cannot exceed that of incoming voltage.)
1.5
2.5
3.8
5.5
1.5
2.3
2.4
2.4
Self-cooling
Forced-air-cooling
A4022
Approx. 50%
Approx. 20% to 40%
Injection braking frequency/time, braking force variable, frequency control available
A4037
3.7
5
5.6
7.1
11.0
8.6
2.4
1/3-phase 200-V Class
Item
Model name (3G3JX-)
Applicable motor
kW
capacity *1
HP
Rated output capacity
(kVA)
200 V
240 V
Rated input voltage
Built-in filter
Rated input current (A)
Rated output voltage *2
Rated output current (A)
Weight (kg)
Cooling method
Braking torque
At short-time
deceleration *3
At capacitor
feedback
DC injection
braking
1/3-phase 200-V Class
AE002
AE004
AE007
AE015
0.2
0.4
0.75
1.5
1/4
1/2
1
2
0.4
0.9
1.3
2.4
0.5
1.0
1.6
2.9
1/3-phase 200 V 15% to 240 V +10%, 50/60 Hz ±5%
None
1.8
3.4
5.2
9.3
3-phase: 200 to 240 V (Cannot exceed that of incoming voltage.)
1.4
2.6
4.0
7.1
0.8
0.9
1.5
2.3
Self-cooling
Forced-air-cooling
AE022
2.2
3
3.4
4.1
13.0
10.0
2.4
Approx. 50%
Approx. 20% to 40%
Injection braking frequency/time, braking force variable, frequency control available
14
Simple, Compact Inverters SYSDRIVE JX Series