DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACT8846 Ver la hoja de datos (PDF) - Active-Semi, Inc

Número de pieza
componentes Descripción
Fabricante
ACT8846 Datasheet PDF : 40 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ACT8846
Rev 4, 25-May-16
REGISTER AND BIT DESCRIPTIONS CONT’D
BLOCK ADDRESS BIT
REG10 0x80 [5:0]
REG10 0x81 [7]
REG10 0x81 [6:3]
REG10 0x81 [2]
REG10 0x81 [1]
REG10 0x81 [0]
REG11 0x90 [7:6]
REG11 0x90 [5:0]
REG11 0x91 [7]
REG11 0x91 [6:3]
REG11 0x91 [2]
REG11 0x91 [1]
REG11 0x91 [0]
REG12 0xA0 [7:6]
REG12 0xA0 [5:0]
REG12 0xA1 [7]
REG12 0xA1 [6:3]
REG12 0xA1 [2]
REG12 0xA1 [1]
REG12 0xA1 [0]
REG13 0xB1 [7]
REG13 0xB1 [6:0]
PB
0xC0
7
PB
0xC0
6
PB
0xC0 [5:2]
PB
0xC0
1
NAME
VSET
ON
-
DIS
nFLTMSK
OK
-
VSET
ON
-
DIS
nFLTMSK
OK
-
VSET
ON
-
DIS
nFLTMSK
OK
ON
-
nPBAMSK
nPBDMSK
-
WDSREN
ACCESS
DESCRIPTION
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kresistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kresistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kresistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R Reserved.
R/W
nPBIN Assertion Interrupt Control. Set this bit to 1 to generate
an interrupt when nPBIN is asserted.
R/W
nPBIN De-assertion Interrupt Control. Set this bit to 1 to
generate an interrupt when nPBIN is de-asserted.
R Reserved.
Watchdog Soft-Reset Enable. Set this bit to 1 to enable
R/W
watchdog function. When the watchdog timer expires, the PMU
commences a soft-reset routine. This bit is automatically reset to
0 when entering sleep mode.
Innovative PowerTM
ActivePMUTM is a trademark of Active-Semi.
I2CTM is a trademark of NXP.
- 14 -
www.active-semi.com
Copyright © 2016 Active-Semi, Inc.

Share Link: 