ACT8846
Rev 1, 15-May-13
REGISTER AND BIT DESCRIPTIONS CONT’D
BLOCK ADDRESS BIT
REG3 0x31 [7:6]
REG3 0x31 [5:0]
REG3
REG3
REG3
0x32 [7]
0x32 [6:3]
0x32 [2]
REG3
REG3
REG4
REG4
REG4
REG4
0x32 [1]
0x32 [0]
0x40 [7:6]
0x40 [5:0]
0x41 [7:6]
0x41 [5:0]
REG4
REG4
REG4
0x42 [7]
0x42 [6:3]
0x42 [2]
REG4
REG4
REG5
REG5
REG5
REG5
0x42 [1]
0x42 [0]
0x50 [7:6]
0x50 [5:0]
0x51 [7]
0x51 [6:3]
REG5 0x51 [2]
REG5
REG5
REG6
REG6
REG6
0x51 [1]
0x51 [0]
0x58 [7:6]
0x58 [5:0]
0x59 [7]
NAME
-
VSET1
ON
-
PHASE
nFLTMSK
OK
-
VSET0
-
VSET1
ON
-
PHASE
nFLTMSK
OK
-
VSET
ON
-
DIS
nFLTMSK
OK
-
VSET
ON
ACCESS
DESCRIPTION
R Reserved.
Secondary Output Voltage Selection. Valid when VSEL is driven
R/W high. See the Output Voltage Programming section for more
information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear bit
to 0 to disable the regulator.
R Reserved.
Regulator Phase Control. Set bit to 1 for the regulator to operate
R/W 180° out of phase with the oscillator, clear bit to 0 for the
regulator to operate in phase with the oscillator.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
Primary Output Voltage Selection. Valid when VSEL is driven low.
R/W See the Output Voltage Programming section for more
information
R Reserved.
Secondary Output Voltage Selection. Valid when VSEL is driven
R/W high. See the Output Voltage Programming section for more
information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear bit
to 0 to disable the regulator.
R Reserved.
Regulator Phase Control. Set bit to 1 for the regulator to operate
R/W 180° out of phase with the oscillator, clear bit to 0 for the
regulator to operate in phase with the oscillator.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear bit
to 0 to disable the regulator.
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kΩ resistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear bit
to 0 to disable the regulator.
Innovative PowerTM
- 12 -
Active-Semi Proprietary―For Authorized Recipients and Customers
ActivePMUTM is a trademark of Active-Semi.
I2CTM is a trademark of NXP.
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.