DC and AC parameters
8
DC and AC parameters
M24512-W M24512-R M24512-DF
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 7. Operating conditions (voltage range W)
Symbol
Parameter
Min.
Max.
VCC
Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. For devices identified by process letter K.
2.5
5.5
–40
85
-
1(1)
Unit
V
°C
MHz
Table 8. Operating conditions (voltage range R)
Symbol
Parameter
Min.
Max.
VCC
Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. For devices identified by process letter K.
1.8
5.5
–40
85
-
1(1)
Unit
V
°C
MHz
Table 9. Operating conditions (voltage range F)
Symbol
Parameter
Min.
Max.
VCC Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. For devices identified by process letter K.
1.7
5.5
–40
85
-
1(1)
Unit
V
°C
MHz
Table 10. AC measurement conditions
Symbol
Parameter
Min.
Max.
Unit
Cbus Load capacitance
-
100
pF
-
SCL input rise/fall time, SDA input fall time
-
50
ns
-
Input levels
0.2 VCC to 0.8 VCC
V
-
Input and output timing reference levels
0.3 VCC to 0.7 VCC
V
24/47