DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TUHS15F15 Ver la hoja de datos (PDF) - Unspecified

Número de pieza
componentes Descripción
Fabricante
TUHS15F15 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
AC-DC Power Supplies PCB Mount Type
Ordering information
TUHS15
TUH S 15 F 12
1
2
3
4
5
1Series name
R
2Single output
3Output wattage
4Universal Input
5Output voltage
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
ClassⅡ
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
TUHS15F12
15.00
12V 1.25A
TUHS15F15
15.00
15V 1A
TUHS15F24
15.12
24V 0.63A
SPECIFICATIONS
MODEL
TUHS15F12
TUHS15F15
TUHS15F24
VOLTAGE[V]
AC85 - 264 1f DC120 - 370
ACIN 100V 0.35typ (Io=100%)
CURRENT[A]
ACIN 200V 0.18typ (Io=100%)
INPUT
FREQUENCY[Hz]
50/60 (47 - 63)
ACIN 100V 85typ
EFFICIENCY[%]
ACIN 200V 85typ
85typ
85typ
86typ
87typ
INRUSH CURRENT
Limited by external components
VOLTAGE[V]
12
15
24
CURRENT[A]
1.25
1
0.63
LINE REGULATION[mV] 48max
60max
96max
LOAD REGULATION[mV] 100max
120max
150max
OUTPUT
30 to 100% Load *1 160max
RIPPLE[mVp-p]
0 to 30% Load
AC85V - 240V
*1
480max
RIPPLE
NOISE[mVp-p]
30 to 100% Load *1 200max
0 to 30% Load
AC85V - 240V
*1
560max
TEMPERATURE
0 to +50C 180max
REGULATION[mV] -40 to +50C 270max
160max
480max
200max
560max
240max
360max
200max
580max
240max
660max
360max
480max
DRIFT[mV]
*2 48max
60max
96max
OUTPUT VOLTAGE SETTING[V] 11.40 - 12.60
14.25 - 15.75
23.00 - 25.00
PROTECTION CIRCUIT OVERCURRENT PROTECTION Works over 105% of rating and recover automatically
AND OTHERS
OVERVOLTAGE PROTECTION[V] 13.20 - 19.20
16.50 - 24.00
26.40 - 38.40
ISOLATION INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
AND NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE
Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B *3
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
33.0X15.0X22.0mm[1.3X0.59X0.86 inches] (WXHXD) / 25g max
Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
* Measured with 68μF capasitor as Cbc.
TUHS-8

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]