GS-C200 / GS-C200S
Command
Description
Gs *
The ”velocity mode” Goto command allows to move the motor continuously, i.e. the motor is
accelerated to the programmed speed and then it slews indefinitely in the selected direction until a
”stop” command is received.
The command is always followed by the direction information.
The command string :
G+
move the motor in the clockwise direction while:
G–
move the motor in the counterclockwise direction. To stop the motor either the Z or the K command
can be used.
The ”velocity mode” Goto command is of the delayed execution type and it occupies 4 memory
locations.
Gsx *
A further possibility offered by the Goto command, that greatly improves the GS-C200 flexibility, is
the ”controlled velocity mode” operation.
This command is followed by the direction information and by the User input to be tested to stop the
operation.
This occurs when a ”zero” level is applied to the specified User input. For example the command
string:
G+2
causes the motor to ramp to the programmed slew speed and to move at this speed until the UI2
input is brought to ”zero”.
The ”controlled velocity mode” Goto command is of the delayed execution type and it occupies 4
memory locations.
Gsxxxxxxx** The Goto command forces the motor to reach the specified target position.
This command, executed exclusively by the GS-C200S, is always followed by an argument whose
value ranges from – 8388608 and + 8388607, and it defines the position to be reached.
The 0 position coincides with the Home position or with the position where an Initialize command
has been sent.
The Goto command is of the delayed execution type and it occupies 4 memory locations.
gs **
The ”velocity mode” Goto command allows to move the motor continuously, i. e. the motor is
accelerated to the programmed speed and then it slews indefinitely in the selected direction until a
”stop” command is received.
g+1
move the motor in the clockwise direction while:
g–
move the motor in the counterclockwise direction.
To stop the motor either the Z or the K command can be used.
The ”velocity mode” Goto command is of the delayed execution type and it occupies 4 memory
locations.
gsx **
An additional possibility offered by the Goto command, further improving the GS-C200S flexibility, is
the ”controlled velocity mode” operation.
This command is followed by the direction information and by the User input to be tested to stop the
operation.
This occurs when a ”zero” level is applied to the specified User input. For example the command
string:
gt1
causes the motor to ramp to the programmed slew speed and to move at this speed until the UI1
input is brought to ”zero”.
The ”controlled velocity mode” Goto command is of the delayed execution type and it occupies 4
memory locations.