HR10 Series●High performance miniature circular connectors
Cable connecting methods
HR10B-2.5CP(73)
HR10B-2.5CJ(73)
1. Cable end treatment
Fig.1
11±0.5
(2.5)
1.4±0.2
3.7±0.2
Slit cable outer jaket
2 pieces (180° reverse side)
1. Dimensions for cable end treatment are shown in Fig 1.
2. Termination is described below.
(1) Strip cable outer jacket as indicated.
(2) Slit outer jacket on both sides per Fig.1.
(3) Fold back outer cover.
(4) Remove insulator from cable.
2. Soldering male pin to cable center conductor
Fig.2
Male pin
Soldering
1. Solder male pin to cable center conductor as indicated in Fig.2.
(1) Pre-solder the solder pot of pin with Ø0.5mm string solder.
(2) Male pin should fit flush against the cable insulator as
shown.
(3) Remove any excess solder from the pin with a knife.This
surface must be smooth.
(4) A properly soldered terminal will yield 500gf when stretched.
Should fix flush
Contact fixing jig such as vise
3. Crimping cable outer conductor
Fig.3
15±0.2
1. Insert the cable into the connector and make sure to push it
all the way in. To confirm that the cable is fully inserted,
make sure that the depth is 1.5 ± 0.2mm by measuring from
the end of the connector to the tip of the male contact by
using a vernier calipers or other suitable measuring device.
2. Use the HR10-TC-01 tool to crimp the metal fitting to the
cable.
Clamp
Connector
Remove excess insulator material
(remaining after clamping is complated)
with a knife or aimilarobject.
12