4.1.5.2 Get Instructions
Get instructions are instructions that read the data from a location in the QT1110 memory map.
Figure 4-7. Positive Recalibration Delay Get Instruction – CRC Disabled
Host (Sends on MOSI)
Device (Responds on MISO)
Command: 0xD5
Response: 0x55 (“Idle†– Fresh Command)
Simultaneous
Transmission
Null: 0x00
“Get†Data: 0x0C (Positive Recalibration Delay)
The host sends the appropriate Get command, followed by a Null byte. The QT1110 returns the contents of the
addressed memory location.
Figure 4-7 on page 15 shows the exchange for a report on the positive recalibration delay (assuming that the data
byte is 0x0C).
With CRC Enabled, this exchange takes 4 bytes, with a command CRC transmitted by the host and a report CRC
returned by the QT1110 (see Figure 4-8).
Figure 4-8. Positive Recalibration Delay Get Instruction – CRC Enabled
Host (Sends on MOSI)
Device (Responds on MISO)
Command: 0xD5
Response: 0x55 (“Idle†– Fresh Command)
Simultaneous
Transmission
Command CRC: 0x68
Response: 0x68 (Expected Command CRC)
Null: 0x00
“Get†Data: 0x0C (Positive Recalibration Delay)
Null: 0x00
“Get†CRC: 0xA3
AT42QT1110-MU / AT42QT1110-AU [DATASHEET]