First Prev 11 12 13 14 15 16 17 18 19 20
High Speed Fuses
North American — FWP 700V: 5-1200A
FWP
Specifications
Description: North American
style stud-mount fuses.
Dimensions: See Dimensions
illustrations.
Ratings:
Volts: — 700Vac
Amps: — 5-1200A
IR: — 200kA RMS Sym.
— 50kA @700Vdc
Agency Information: CE, UL Recognition & CSA
Component Acceptance on 5-800A
Electrical Characteristics
Total Clearing I2t
1.5
The total clearing I2t at rated
K
voltage and at power factor of 1.0
15% are given in the electrical
2)
characteristics. For other volt-
0.5
ages, the clearing I2t is found
by multiplying by correction
1)
factor, K, given as a function
0.3
0.2
of applied working voltage,
Eg, (rms).
0.15
316
3)
Eg
460
604 700
1) 35-100A Range
2) 125-600A Range
3) 700-1200A Range
Dimensions (in)
Amp
Range
Fig. A
B
C
DE
F
GH
5-30
1 2.870 0.563 1.855 2.4772.477 0.250 0.4050.063
35-60
1 4.375 0.813 2.750 3.7083.312 0.344 0.7250.125
70-100 1 4.406 0.947 2.594 3.6253.563 0.344 0.7500.125
125-200 1 5.090 1.500 2.840 4.1903.500 0.410 1.0000.250
225-400 1 5.090 2.000 2.840 4.2803.530 0.410 1.5000.250
450-600 1 7.090 2.500 2.840 5.7204.190 0.530 2.0000.380
700-800 1 6.630 2.000 2.844 5.5625.062 0.625 1.5000.250
900-1000 2 See Drawing
1200
3 See Drawing
1mm = 0.0394” / 1” = 25.4mm
I
0.250
0.542
0.375
0.750
0.780
1.300
0.875
Fig. 1: 5-800A
J
Fig. 2: 900-1000A
1.375
Fig. 3: 1200A
3.500
0.125
0.500
AD EC
5.966 3.844
7.594 5.154
F
G
H
B
0.625
3.500
9.590 6.840
1.031
2.750
0.5
4.250
3.844
10.844
0.625
1.625
1.750
0.750
Arc Voltage
2
This curve gives the peak arc 1.6 UL
voltage, UL, which may
1.4
1.2
appear across the fuse dur- 103
1)
ing its operation as a function
of the applied working volt- 8
2)
age, Eg, (rms) at a power
factor of 15%.
6
5
4
Power Losses
Eg
3
Watts loss at rated current is
given in the electrical charac-
300 400 500 600 700
1) 125-600A Range
2) 35-100 & 700-1200A Range
teristics. The curve allows
the calculation of the power
losses at load currents lower
than the rated current. The
1.0
0.8
Kp
0.6
0.5
correction factor, Kp, is given 0.4
as a function of the RMS
0.3
load current, Ib, in % of the 0.2
rated current.
0.1
Ib
Catalog Numbers
30 40 50 60 70 80 90 100%
Electrical Characteristics
Rated
I2t (A2 Sec)
Catalog
Current
Clearing Watts
Numbers
RMS-Amps Pre-arc
at 700V
Loss
FWP-5B
5
1.6
10
1.5
FWP-10B
10
3.6
20
4
FWP-15B
15
10
75
5.5
FWP-20B
20
26
180
6
FWP-25B
25
44
340
7
FWP-30B
30
58
450
9
FWP-35B
35
34
160
12
FWP-40B
40
76
320
12
FWP-50B
50
135
600
12
FWP-60B
60
210
950
15.5
FWP-70B
70
305
2000
18
FWP-80B
80
360
2400
21
FWP-90B
90
415
2700
25
FWP-100B
100
540
3500
27
FWP-125A
125
1800
7300
28
FWP-150A
150
2900
11700
32
FWP-175A
175
4200
16700
35
FWP-200A
200
5500
22000
43
FWP-225A
225
7700
31300
45
FWP-250A
250
10500
42500
48
FWP-300A
300
17600
71200
58
FWP-350A
350
23700
95600
65
FWP-400A
400
31000
125000
78
FWP-450A
450
36400
137000
94
FWP-500A
500
45200
170000 107
FWP-600A
600
66700
250000 122
FWP-700A
700
54000
300000 125
FWP-800A
800
78000
450000 140
FWP-900A
900
91500
530000 150
FWP-1000A 1000
120000
600000 170
FWP-1200A 1200
195000
1100000 190
• Watts loss provided at rated current.
• See accessories on page 106.
Features and Benefits
• Excellent dc performance
• Low arc voltage and low
energy let-through (I2t)
• Superior cycling capability
Typical Applications
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp