M61880FP
Electrical Characteristics
(Unless specified otherwise noted, VCC = 5 V ±5%, Ta = -20ºC to +70ºC)
Limits
Item
Symbo Min.
l
Typ. Max. Unit Test Conditions
“H” input voltage DATA
VIH
2.0
V
ENB, S/H
2.0
V
“L” input voltage DATA
VIL
0.8 V
ENB, S/H
0.8 V
Reference
Vr
voltage input
Vr
0.35
1.5 2.0 V
Reference
Vref
Vref
1.4
voltage output Temperature
coefficient
1.5 1.6
0.1
−0.1
V
mV/°C
Io = ±10µA
Ta = −20 to 25°C
Ta = 25 to 70°C
Operating
LD
VLD
2.5
Vcc V
ILD = 75mA
voltage range
Effective voltage CH
VI
2.7
3.0
V
upper limit
“H” output
CH
voltage
VOH
Vcc−1.6
V
ENB = “L”, IOH = (−0.6mA)
“L” output
CH
VOL
0.6 V
ENB = “L”, IOL = (0.6mA)
voltage
Input voltage
DATA, ENB II
20
µA
VI = 2.7V
−0.2
mA
VI = 0.4V
Switching
LD
Isw
current (Note)
75
mA
CH = 3.5V, Rs = 1.2kΩ, VLD = 3V
Bias current
LD
IB
(Note)
20
mA
VB = 1.4V, RB = 70kΩ, VLD = 3V
Load charge
CH
current
Icg
−0.2
−0.1 −0.66 mA
ENB = “L”, Vo = (0.6 to Vcc−1.6V)
Load discharge CH
current
Idg
0.66
1.0 2.0 mA
ENB = “L”, Vo = (0.6 to Vcc−1.6V)
Off-state output CH
current
Ioz
−0.5
0.5 µA
Vo = 2.0 to 3.0V, hold state
Off output
LD
current
LOFF
50
µA
50
µA
ENB = “L”, DATA = “H”, Isw = 50mA
ENB = “H”, DATA = “L”, Isw = 50mA
Power supply
Icc
43 63
mA
Vcc = 5.25V, ENB = DATA = 0V
current
43 63
0V, CH = 2.5V,
VB = 1.5V, Rs =
820Ω, RB = 75 Ω
Ro = LD = 5.0V
DATA = 4.5V
* Reference values are values when Ta = 25ºC and VCC = 5 V.
Note: These items indicate input voltage/output current conversion characteristics. The M61880 should be used with
ISW and IB within the Specification Value range given in “Recommended Operating Conditions.”
Rev.1.0, Sep.19.2003, page 8 of 20