Figure 1. AUTOMATIC PAGE PROGRAM FLOW CHART
START
BYTE/VPP=VHH
Write Data AAH Address 5555H
Write Data 55H Address 2AAAH
Write Data A0H Address 5555H
Write Program Data/Address
P/N: PM0615
Loading End?
NO
YES
Wait 100us
BYTE/VPP=VIH/VIL
Read Status Register
NO
SR7 = 1
?
YES
NO
SR4 = 0
?
YES
Page Program Completed
Program Error
YES
Program
another page?
NO
Operation Done, Device Stays At Read S.R. Mode
12
To Continue Other Operations,
Do Clear S.R. Mode First
Note : S.R. Stands for Status Register