200
180 1.5
3.0
160 2.0
3.5
140 2.5
120 3.0
3.5
tr/f – TRANSMITTER
OUTPUT OPTICAL
RISE/FALL TIMES – ns
100
1280 1300 1320 1340 1360 1380
λC – TRANSMITTER OUTPUT OPTICAL
CENTER WAVELENGTH –nm
HFBR-1115T FDDI TRANSMITTER TEST RESULTS
OF λC, ∆λ AND tr/f ARE CORRELATED AND
COMPLY WITH THE ALLOWED SPECTRAL WIDTH
AS A FUNCTION OF CENTER WAVELENGTH FOR
VARIOUS RISE AND FALL TIMES.
Figure 9. HFBR-1115T Transmitter
Output Optical Spectral Width
(FWHM) vs. Transmitter Output
Optical Center Wavelength and Rise/
Fall Times.
1.25
1.025
1.00
0.975
0.90
0.50
4.40
1.975
0.075
10.0
5.6
100% TIME
INTERVAL
40 ± 0.7
± 0.725
± 0.725
4.850
1.525
0.525
0% TIME
INTERVAL
0.10
0.025
0.0
-0.025
-0.05
5.6
10.0
1.525
0.525
4.850
80 ± 500 ppm
TIME – ns
0.075
1.975
4.40
THE HFBR-1115T OUTPUT OPTICAL PULSE SHAPE FITS WITHIN THE BOUNDARIES
OF THE PULSE ENVELOPE FOR RISE AND FALL TIME MEASUREMENTS.
Figure 10. Output Optical Pulse Envelope.
5
4
3
2.5 x 10-10 BER
2
1.0 x 10-12 BER
1
-31.0 dBm
-45.0 dBm
PA (PO + 1.5 dB
< PA < -31.0 dBm)
INPUT OPTICAL POWER
(> 1.5 dB STEP INCREASE)
MIN (PO + 4.0 dB OR -31.0 dBm)
PO = MAX (PS OR -45.0 dBm)
(PS = INPUT POWER FOR BER < 102)
INPUT OPTICAL POWER
(> 4.0 dB STEP DECREASE)
0
-4 -3 -2 -1 0 1 2 3 4
EYE SAMPLING TIME POSITION (ns)
SIGNAL DETECT (ON)
SIGNAL DETECT (OFF)
AS MAX
ANS MAX
CONDITIONS:
1.TA = 25° C
2. VCC = 5 Vdc
3. INPUT OPTICAL RISE/FALL TIMES = 1.0/2.1 ns.
4. INPUT OPTICAL POWER IS NORMALIZED TO
CENTER OF DATA SYMBOL.
5. NOTE 21 AND 22 APPLY.
Figure 11. HFBR-2115T Receiver
Relative Input Optical Power vs. Eye
Sampling Time Position.
TIME
AS MAX — MAXIMUM ACQUISITION TIME (SIGNAL).
AS MAX IS THE MAXIMUM SIGNAL DETECT ASSERTION TIME FOR THE STATION.
AS MAX SHALL NOT EXCEED 100.0 µs. THE DEFAULT VALUE OF AS MAX IS 100.0 µs.
ANS MAX — MAXIMUM ACQUISITION TIME (NO SIGNAL).
ANS MAX IS THE MAXIMUM SIGNAL DETECT DEASSERTION TIME FOR THE STATION.
ANS MAX SHALL NOT EXCEED 350 µs. THE DEFAULT VALUE OF AS MAX IS 350 µs.
Figure 12. Signal Detect Thresholds and Timing.