4.2. HAL740
The HAL740 consists of two independent unipolar
switches (see Fig. 4–5) with complementary magnetic
characteristics controlling two independent open-drain
outputs. The Hall plates of the two switches are
spaced 2.35 mm apart.
The S1-Output turns low with the magnetic north pole
on the branded side of the package and turns high if
the magnetic field is removed. It does not respond to
the magnetic south pole on the branded side.
The S2-Output turns low with the magnetic south pole
on the branded side of the package and turns high if
the magnetic field is removed. It does not respond to
the magnetic south pole on the branded side.
Magnetic Features
– two independent Hall-switches
– distance of Hall plates: 2.35 mm
– temperature coefficient of 2000 ppm/K in all mag-
netic characteristics
– operation with static magnetic fields and dynamic
magnetic fields up to 10 kHz
Applications
The HAL740 is the ideal sensor for applications which
require both magnetic polarities, such as:
– position and direction detection, or
– position and end point detection with either mag-
netic pole (omnipolar switch).
Output Voltage
VO
BHYS
BON,S1 BOFF,S1 0
BHYS
VOL
BOFF,S2 BON,S2 B
Fig. 4–5: Definition of magnetic switching points for
the HAL740
Magnetic Characteristics
(quasistationary: dB/dT < 0.5 T/ms) at TJ = 40 °C to +100 °C, VDD = 3.8 V to 24 V,
Typical Characteristics for VDD = 12 V. Absolute values common to both Hall switches. The Hall switches S1 and S2
only differ in sign. For S1 the sign is negative, for S2 positive. Positive flux density values refer to the magnetic south
pole at the branded side of the package.
Parameter
On point BON
TJ
Min. Typ. Max.
40 °C 8.5
12.3 16.0
25 °C 7.0
11.5 16.0
100 °C 5.5
10.8 16.0
140 °C 4.6
10.4 16.0
Off point BOFF
Min. Typ. Max.
5.0
8.8
12.5
3.5
8.0
12.5
2.0
7.0
12.5
1.1
6.8
12.5
Hysteresis BHYS
Min. Typ. Max.
2.0
5.5
2.0
6.0
1.5
6.5
1.0
7.0
Magnetic Offset
Min. Typ. Max.
10.6
9.8
8.9
8.6
Unit
mT
mT
mT
mT
The hysteresis is the difference between the switching points BHYS = BON BOFF
The magnetic offset is the mean value of the switching points BOFFSET = (BON + BOFF) / 2