PIO SINK CURRENT
DS2406
I SA , I SB 100 mA
@ 0.4V
90 mA
80 mA
70 mA
60 mA
50 mA
40 mA
30 mA
20 mA
10 mA
2.8V
max.
PIO-A
min.
max.
PIO-B
min.
V PUP
4V
5V
6V
NOTES:
1. All voltages are referenced to ground.
2. VPUP, VPUPA, VPUPB = external pull-up voltage.
3. Input load is to ground.
4. An additional reset or communication sequence cannot begin until the reset high time has expired.
5. Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1 µs of this falling edge and will remain valid for 14 µs minimum (15
µs total from falling edge on 1-Wire bus).
6. VIH is a function of the chip-internal supply voltage. This voltage is determined by either the external
pull-up resistor and VPUP or the VCC supply, whichever is higher. Without VCC supply, VIH for either
PIO pin should always be greater than or equal to VPUP -0.3V.
7. Capacitance on the data pin could be 800 pF when power is first applied. If a 5 kresistor is used to
pull up the data line to VPUP, 5 µs after power has been applied the parasite capacitance will not affect
normal communications.
8. tRSTL should be limited to maximum 5 ms. Otherwise a parasitically powered DS2406 may perform a
power-on reset.
9. Input resistance is to ground.
10. VCC must be at least 4.0V if it is to be connected during a programming pulse.
11. If the current at PIO-A reaches 200 mA the gate voltage of the output transistor will be reduced to
limit the sink current to 200 mA. The user-supplied circuitry should limit the current flow through the
PIO-transistor to no more than 100 mA. Otherwise the DS2406 may be damaged.
12. PIO-A has a controlled turn-on output. The indicated currents are DC values. At VPUP = 4.0V or
higher the sink current typically reaches 80% of its DC value 1 µs after turning on the transistor.
13. Under certain low voltage conditions VILMAX may have to be reduced to as much as 0.5V to always
guarantee a presence pulse.
14. The accumulative duration of the programming pulses for each address must not exceed 5 ms.
15. The optimal sampling point for the master is as close as possible to the end time of the 15 µs tRDV
period without exceeding tRDV. For the case of a Read-one time slot, this maximizes the amount of
time for the pull-up resistor to recover the line to a high level. For a Read-zero time slot it ensures
that a read will occur before the fastest 1-Wire devices(s) release the line (tRELEASE = 0).