X76F641
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max. Units
Test Conditions
ICC1
VCC Supply Current
(Read)
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 KHz,
1
mA SDA = Open
RST = VSS
ICC2(3)
VCC Supply Current
(Write)
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 KHz,
3
mA SDA = Open
RST = VSS
ISB1(1)
VCC Supply Current
(Standby)
50
µA
VIL = VCC x 0.1, VIH = VCC x 0.9
fSCL = 400 KHz, fSDA = 400 KHz
ISB2(1)
VCC Supply Current
(Standby)
1
µA
VSDA = VSCC = VCC
Other = GND or VCC–0.3V
ILI
Input Leakage Current
10
µA VIN = VSS to VCC
ILO
Output Leakage Current
10
µA VOUT = VSS to VCC
VIL1(2) Input LOW Voltage
–0.5 VCC x 0.3 V VCC = 5.5V
VIH1(2) Input HIGH Voltage
VCC x 0.7 VCC + 0.5 V VCC = 5.5V
VIL2(2) Input LOW Voltage
–0.5 VCC x 0.1 V VCC = 2.0V
VIH2(2) Input HIGH Voltage
VCC x 0.9 VCC + 0.5 V VCC = 2.0V
VOL
Output LOW Voltage
0.4
V IOL = 3mA
7002 FM T07
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
Test
Max.
Units
Conditions
COUT(3)
Output Capacitance (SDA)
8
CIN(3)
Input Capacitance (RST, SCL)
6
pF
VI/O = 0V
pF
VIN = 0V
NOTES: (1) Must perform a stop command after a read command prior to measurement
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
7002 FM T08
EQUIVALENT A.C. LOAD CIRCUIT
OUTPUT
5V
1533Ω
OUTPUT
100pF
3V
1.3KΩ
100pF
7025 FM 17
A.C. TEST CONDITIONS
Input Pulse Levels
VCC x 0.1 to VCC x 0.9
Input Rise and Fall Times
10ns
Input and Output Timing Level
VCC x 0.5
Output Load
100pF
7002 FM T09