VIPer20/SP/DIP - VIPer20A/ASP/ADIP
AVALANCHE CHARACTERISTICS
Symbol
Parameter
Max Value
Unit
Avalanche Current, Repetitive or Not Repetitive
ID(AR)
(pulse widht limited by Tj max; δ < 1%)
for VIPer20/SP/DIP
0.5
A
for VIPer20A/ASP/ADIP
(see fig.12)
0.4
A
E(ar)
Single Pulse Avalanche Energy
(starting Tj =25ºC, ID=ID(ar))
(see fig.12)
10
mJ
ELECTRICAL CHARACTERISTICS (Tj=25°C; VDD=13V, unless otherwise specified)
POWER SECTION
Symbol
Parameter
BVDSS Drain-Source Voltage
Test Conditions
ID=1mA; VCOMP=0V
for VIPer20/SP/DIP
for VIPer20A/ASP/ADIP (see fig.5)
Min Typ Max Unit
620
V
700
V
VCOMP=0V; Tj=125°C
IDSS Off-State Drain Current VDS=620V for VIPer20/SP/DIP
VDS=700V for VIPer20A/ASP/ADIP
1.0
mA
1.0
mA
RDS(on)
Static Drain-Source
On Resistance
tf
tr
Coss
Fall Time
Rise Time
Output Capacitance
ID=0.4A
for VIPer20/SP/DIP
for VIPer20A/ASP/ADIP
ID=0.4A; Tj=100°C
for VIPer20/SP/DIP
for VIPer20A/ASP/ADIP
ID=0.2A; VIN=300V (1)
(See fig. 3)
ID=.4A; VIN=300V (1)
(See fig. 3)
VDS=25V
13.5 16
Ω
15.5 18
Ω
29
Ω
32
Ω
100
ns
50
ns
90
pF
(1) On Inductive Load, Clamped.
SUPPLY SECTION
Symbol
IDDch
IDD0
IDD1
IDD2
VDDoff
VDDon
VDDhyst
Parameter
Test Conditions
Start-Up Charging
Current
VDD=5V; VDS=35V
(see fig. 2 and fig. 15)
Operating Supply Current VDD=12V; FSW=0kHz
(see fig. 2)
Operating Supply Current VDD=12V; Fsw=100kHz
Operating Supply Current VDD=12V; Fsw=200kHz
Undervoltage Shutdown (See fig. 2)
Undervoltage Reset
(See fig. 2)
Hysteresis Start-up
(See fig. 2)
Min Typ Max Unit
-2
mA
12
16
mA
13
mA
14
mA
7.5
8
9
V
11
12
V
2.4
3
V
4/25