STP08DP05
Detection mode functionality
10.3
Phase three: “resuming to normal mode”
The sequence for re-entering in normal mode is showed in the following table and diagram:
Table 13. Resuming to normal mode timing diagram
CLK
1°
2°
3°
4°
5°
OE/DM2
H
L
H
H
H
LE/DM1
L
L
L
L
L
Figure 19. Resuming to normal mode timing diagram
Note:
For proper device operation the “entering in detection” sequence must be follow by a
“resume mode” sequence, isn’t possible to insert consecutive equal sequence.
10.4
Note:
Error detection conditions
VDD = 3.3 to 5 V temperature range 25 °C.
Table 14. Detection condition
SW-1 or SW-3b
Open line or output
short to GND detected
==> IODEC 0.5 x IO
No error
detected
SW-2 or SW-3a
Short on LED or short
to V-LED detected
==> VO 2.5V
No error
detected
==> IODEC 0.5 x IO
==> VO 2.2 V
Where: IO = the output current programmed by the REXT,
IODEC = the detected output current in detection mode.
DocID13405 Rev 6
19/32