DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SA9604APA Ver la hoja de datos (PDF) - South African Micro Electronic Systems

Número de pieza
componentes Descripción
Fabricante
SA9604APA Datasheet PDF : 20 Pages
First Prev 11 12 13 14 15 16 17 18 19 20
SA9604A
Example:
V = 230V
I = 80A
Active Power = 230V x 80A x (n/t)/640000
Reactive Power = 230V x 80A (n/t)/(640000 x 2)/Pi)
n=
Difference in register values between successive reads (delta
value)
t=
Time difference between successive reads (in seconds)
To calculate the measured voltage, the following formula is applied:
V = measured
V *n
940 000 * t
Where V =
t=
n=
Rated Voltage
Time difference between successive reads
Difference in register values between
successive reads
The Voltage calculated is the average voltage. The voltage measurement will give
an accuracy of better than 1% for a voltage range of 50% to 115% of the rated mains
voltage if the voltage is a pure sine wave.
The mains frequency may be calculated as follows:
Frequency =
Crystal frequency
Register Value * 2
7. Calibration
For accurate results we would recommend the following software calibration
procedure:
7.1 Active energy
Establish a calibration factor for active energy (Ka) at pf close to 1.
Active Measured = Active_Register_Value x Ka
14/20