DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SA2532AP Ver la hoja de datos (PDF) - South African Micro Electronic Systems

Número de pieza
componentes Descripción
Fabricante
SA2532AP
Sames
South African Micro Electronic Systems Sames
SA2532AP Datasheet PDF : 22 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
SA2532
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
The values are valid during automatic dialling and are minimum values during
manual dialling, i.e. the tones will continue as long as the key is depressed.
The rise time is the time from 10% of final value until the tone amplitude has reached
90% of its final value.
Relative to high group.
The FCI circuit is reset by POR and HS/DP pulled high (off-hook). After a reset the
FCI circuit is in a standby state. A positive edge on FCI will start a 73ms timer and
the frequency discrimination is initiated. Whenever a period of the ring signal is
missing, the timer is reset. When a valid ring signal is present for 73ms, the
melody generator is started and is directly controlled by the ring signal. This
condition will remain until a new reset.
This does not include the frequency deviation of the ceramic resonator.