DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PCF8531 Ver la hoja de datos (PDF) - Philips Electronics

Número de pieza
componentes Descripción
Fabricante
PCF8531
Philips
Philips Electronics Philips
PCF8531 Datasheet PDF : 44 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Philips Semiconductors
34 × 128 pixel matrix driver
Product speciï¬cation
PCF8531
8.18.8 LCD BIAS VOLTAGE
Table 3 Intermediate LCD bias voltages
SYMBOL
BIAS
VOLTAGES
EXAMPLE FOR
1â„7 BIAS
V1
VLCD
VLCD
V2
nn-----++-----34-- × VLCD
6â„7 × VLCD
V3
nn-----++-----24-- × VLCD
5â„7 × VLCD
V4
n-----+2-----4-- × VLCD
2â„7 × VLCD
V5
n-----+1-----4-- × VLCD
1â„7 × VLCD
V6
VSS
VSS
8.18.9 SET VOP VALUE:
The operating voltage VLCD can be set by software.
The voltage at reference temperature [VLCD (T = Tcut)] can
be calculated as: VLCD (Tcut) = (a + VOP × b).
The generated voltage is dependent on the temperature,
programmed Temperature Coefficient (TC) and the
programmed voltage at reference temperature (Tcut).
VLCD = VLCD (Tcut) × [1 + TC × (T − Tcut)].
The parameter values are given in Table 4.
Two overlapping VLCD ranges can be selected via the
command ‘HV-gen control’ (see Table 4 and Fig.8).
The maximum voltage that can be generated depends on
the VDD2 and VDD3 voltages and the display load current.
For Mux 1 : 34, the optimum operating voltage of the liquid
can be calculated as:
VLCD
=
----------1-----+---------3---4------------
2
×


1
–
----1-3---4--
×
Vt
h
=
5.30 × Vth
Where Vth is the threshold voltage of the liquid crystal
material used.
The practical value for VOP is determined by equating
Voff(rms) with a defined LCD threshold voltage (Vth),
typically when the LCD exhibits approximately
10% contrast.
As the programming range for the internally generated
VLCD allows values above the maximum allowed VLCD, the
user has to ensure, while setting the VOP register and
selecting the temperature compensation, that the VLCD
limit of maximum 9 V will never be exceeded under all
conditions and including all tolerances.
Table 4 Parameter values for the HV generator programming
SYMBOL
Tcut
a
b
Programming range
VALUE
PRS = 0
27
2.94
0.03
2.94 to 6.75
PRS = 1
27
6.75
0.03
6.75 to 10.56
UNIT
°C
V
V
V
2000 Feb 11
14