15W DC-DC Converter P15C-Series
Specifications
Input
Voltage range
Filter
Input surge voltage for
100mS max.
Remote CTRL
Remote CTRL input current
Remote CTRL input reference
Output
Power
Voltage accuracy
Trim adjustment range
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Line voltage regulation
Load voltage regulation 10%
to full load
Transient response recovery time
Temperature coefficient
Minimum load
24V type : 9 ... 36 VDC
48V type : 18 … 75 VDC
HV type : 20 … 72 VDC
π Pi type
24V type : 50 VDC max.
48V type : 100 VDC max.
On: open or 3.5..12 VDC
Off : 0...1.2 VDC
-2.5mA
-Input
15W max
± 2%
±10 %
5, 12, 15 V type: 75 mVp-p
110 V type: 100mVp-p
140 V type: 250mVp-p
Hiccup, automatics recovery
± 0.5%
single: ± 1%
dual: ± 5%
110 V,140 V type: ± 1%
500 µs at 25 % load chance
± 0.02% / °C
10 % to maintain the
specified regulation
General
Efficiency
Switching frequency
Isolation voltage
Isolation Resistance
Isolation Capacitance
MTBF
Standard in accordance with
Environmental
Operating temperature
Storage temperature
Maximum case temp.
Thermal impedance
Thermal shock
Vibration
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Conducted & radiated emissions
See table
300 kHz, typ.
1600 VDC
109 min.
300 pF, max.
2x106 hrs
EN60950, IEC60950, UL1950
-40 °C to +85 °C
(with derating)
-55 °C to +105 °C
+100 °C
10°C/W
8.24 °C/W with heat-sink 7G-0011A
MIL-STD-810D
2G, 10-55 Hz, 30 min., XYZ-axis
5% to 95% RH
Free-air convection
2 x 1.6 x 0.4 inches
50.8 x 40.6 x 10.4 mm
48 g
Nickel-coated copper
Epoxy (UL94-V0)
EN55022 Level A
Dimensions
Derating
All dimensions in inches (mm)
Pin Pitch tolerance ±0.014 (0.35)
Pin connections
Pin Single
1
+ Input
2
- Input
4
CTRL
5
No pin
6
+ Output
7
- Output
8
Trim
Dual
+ Input
- Input
CTRL
+ Output
Common
- Output
Trim
Life Support Policy: HY-LINE does not authorize the use of
any of its products for use in life support devices or systems
without the express written approval of an officer of the
Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used
in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant
injury to the user.
Rev: 04 / 2005 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: power@hy-line.de
Schweiz:
Gründenstraße 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: power@hy-line.ch