NCV7382
ESD/EMC Remarks
General Remarks
Electronic semiconductor products are sensitive to
Electro Static Discharge (ESD). Always observe Electro
Static Discharge control procedures whenever handling
semiconductor products.
ESD Test
The NCV7382 is tested according to MIL883D (human
body model).
EMC
The test on EMC impacts is done according to ISO
7637−1 for power supply pins and ISO 7637−3 for data and
signal pins.
POWER SUPPLY PIN VS
Test Pulse
1
2
3a/b
5
Condition
t1 = 5.0 s/US = −100 V/tD = 2.0 ms
t1 = 0.5 s/US = 100 V/tD = 0.05 ms
US = −150 V/US = 100 V
Burst 100 ns/10 ms/90 ms Break
Ri = 0.5 W, tD = 400 ms
tr = 0.1 ms/UP + US = 40 V
Duration
5000 Pulses
5000 Pulses
1h
10 Pulses Every 1 Min
DATA AND SIGNAL PINS EN, BUS
Test Pulse
Condition
1
t1 = 5.0 s/US = −100 V/tD = 2.0 ms
2
t1 = 0.5 s/US = 100 V/tD = 0.05 ms
3a/b
US = −150 V/US = 100 V
Burst 100 ns/10 ms/90 ms Break
Duration
1000 Pulses
1000 Pulses
1000 Burst
http://onsemi.com
15