MX29LV017B
COMMAND DEFINITIONS
Device operations are selected by writing specific ad-
dress and data sequences into the command register.
Writing incorrect address and data values or writing them
in the improper sequence will reset the device to the
read mode. Table 4 defines the valid register command
sequences. Note that the Erase Suspend (B0H) and
Erase Resume (30H) commands are valid only while the
Sector Erase operation is in progress.
TABLE 4. MX29LV017B COMMAND DEFINITIONS
First Bus Second Bus Third Bus Fourth Bus
Command
Bus Cycle
Cycle
Cycle
Cycle
Cycle Addr Data Addr Data Addr Data Addr Data
Reset
1 XXXH F0H
Read
1 RA RD
Read Silicon ID
4 XXXH AAH XXXH 55H XXXH 90H ADI DDI
Sector Protect
4 XXXH AAH XXXH 55H XXXH 90H (SA) 00H
Verify
x02H 01H
Byte Program
4 XXXH AAH XXXH 55H XXXH A0H PA PD
Chip Erase
6 XXXH AAH XXXH 55H XXXH 80H XXXH AAH
Sector Erase
6 XXXH AAH XXXH 55H XXXH 80H XXXH AAH
Sector Erase Suspend 1 XXXH B0H
Sector Erase Resume 1 XXXH 30H
CFI Query
1 XXXH 98
Fifth Bus
Sixth Bus
Cycle
Cycle
Addr Data Addr Data
XXXH 55H XXXH 10H
XXXH 55H SA 30H
Notes:
1. ADI = Address of Device identifier; A1=0, A0 = 0 for manufacturer code,A1=0, A0 = 1 for device code. A2-A20=do
not care.
(Refer to table 2)
DDI = Data of Device identifier : C2H for manufacture code, C8H for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read. RD=Data to be read at location RA.
2. PA = Address of memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address of the sector to be erased.
3. For Sector Protect Verify operation:If read out data is 01H, it means the sector has been protected. If read out data
is 00H, it means the sector is still not being protected.
4. Any number of CFI data read cycles are permitted.
5. The reset command is required to return to the read mode when the device is in the automatic select mode or if Q5
goes high.