Preliminary
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
VDD
Supply voltage
Vi
Input voltage
Vo
Output voltage
Pd
Power dissipation
Topr
Operating temperature
T stg
Storage temperature
MITSUBISHI STORAGE CARD
MF6XXXX-02BJXX series
FLASH DRIVES
Conditions
With respect to GND
Ta = 25 °C
Ratings
Unit
-0.3~6.2
V
-0.3~VDD+0.3
V
-0.3~VDD+0.3
V
1.2
W
0~60
°C
-10~80
°C
RECOMMENDED OPERATING CONDITIONS
Symbol
VDD(5V)
GND
VIH
VIL
VDD Supply voltage
System ground
High input voltage
Low input voltage
Parameter
Min.
4.5
0.7VDD
0
Limits
Typ.
5.0
0
Max.
Unit
5.5
V
V
VDD
V
0.8
V
DC ELECTRICAL CHARACTERISTICS (Ta=0~60°C, VDD=5V±10%, unless otherwise noted)
Symbol
Parameter
Test Condition
VOH
High output voltage IOH=4mA(4.5V)
INTRQ,
INPACK#,
DASP#,
PDIAG#
IOH=8mA(4.5V)
the other
outputs
VOL
Low output voltage IOL=-4mA(4.5V)
INTRQ,
INPACK#,
DASP#,
PDIAG#
IOL=-8mA(4.5V)
the other
outputs
IOZ
Output current in off CS0# = CS1# = VIH DD15-DD0
state
ICCR
Active supply current Output open
(Read)
ICCW
Active supply current
(Write)
ICCS
Standby current
CS0# = CS1# = VDD
(Auto power down) DD15-DD0 = GND
Other inputs = VDD or GND
ICCD
Sleep current
CS0# = CS1# = VDD
(Sleep command)
DD15-DD0 = GND
Other inputs = VDD or GND
Min.
4.5V
0.8VDD
-
-
Limits
Typ.
70
100
2.0
500
Max.
Unit
5.5V
-
V
0.4
V
±10
µA
110
mA
140
mA
4.0
mA
800
µA
MITSUBISHI
ELECTRIC
13/18